e.  Once  you  have  replaced  one  of  the  cartridges/membrane  –  with  the  faucet 

(Figure 2) open – open the brass ball valve (Figure 5) at the water supply. Let 
all of the air out from inside the ultrafiltration system. Once a continual water 
flow comes out of the faucet, let it run for 30 seconds and then close the fau-
cet.  If  in  the  beginning,  the  water  runs  black,  don’t  worry,  this  is  normal,  it’s 
caused by the residue that the granulated carbon filter lets off. Drain this wa-
ter.  The  water  will  run  clear  not  long  after  this.  Check  for  leaks,  if  there  are 
any, close the valves and fix them. 

 

Precaution 1: If there is any water leak in any area of the tube connections, 

remove  it  and  cut  off  0.5cm.  Then  reconnect  it.  If  the  leak  s 
produced on any thread, unscrew the piece, apply more Teflon 
and screw it back on. 

 

6.2.  PROCEDURE  FOR  REPLACING  THE  WATERSTOP  ANTILEAK  ABSOR-
BENT MATERIAL 

 

 

In  the  case  of  having  to  change  the WATER  STOP  Antileak  absorbent 

material; you must do as follows: 

a.  Raise  the  arm  on  the  WATER  STOP  Antileak  system,  to  cut  off  the  water 

supply (if there is a leak the arm will already be raised). 

 

b.  Throw away the current absorbent material. 

 

c.  Replace it with a new absorbent material. 

 

d.  Lower the arm on the WATER STOP Antileak system and it’s ready for use. 

 

 

 
 
 
 

Summary of Contents for NELVA

Page 1: ... 4 3 ULTRAFILTRATION SYSTEM INSTALLATION 8 5 ULTRAFILTRATION SYSTEM START UP 10 6 INSTRUCTIONS AND MAINTENANCE 12 6 1 PROCEDURE FOR REPLACING CARTRIDGES AND THE MEMBRANE 13 6 2 PROCEDURE FOR REPLACING THE WATERSTOP ANTILEAK ABSOR BENT MATERIAL 10 7 FAULTS PROBABLE CAUSES AND POSSIBLE SOLUTIONS 15 8 SPARE PARTS 16 9 MONITORING AND MAINTENANCE CONTROL 20 ...

Page 2: ...above 40ºC to avoid damaging the system The ultrafiltration system is designed to treat tap water with a maximum salinity of 1500 ppm Do not use in places where the water is not microbiologically safe or has an unknown quality For water with a greater salinity level please con tact an official HIDRO WATER S L distributer It is advisable that the water to be treated has been softened or with a maxi...

Page 3: ...f the system For installation maintenance and cartridge change please follow this manual otherwise the warranty will be void 3 CHECKING THE CONTENTS Open the packaging and make sure that all of the components are inside ready for the installation Figure Description 1 NELVA ultrafiltration system main unit 2 Faucet 3 PE Tube 4 Feed adapter 5 M x T Brass ball valve 6 plastic insert 7 faucet tube ada...

Page 4: ...ucet installation Figure 2 a Choose the location on the counter where you want to install the faucet b Use a drill with a 12mm bit to make a neces sary sized hole to put the faucet c Fit the tap in the hole as indicated in the figure using a spanner our reference OI 0207 128 not supplied with system to adjust it tightening the nut X 1 X 1 X 1 X 1 Figure 1 Figure 2 Figure 3 Figure 4 X 1 X 2 X 1 X 1...

Page 5: ... ball valve is closed 4 3 Ultrafiltration system installation The hydraulic connections should follow the contour of the surface cho sen for installation so that the tubes do not get mixed up or tangled Leave a sufficient length of tube to ease moving the system during future maintenance Here are the steps to follow to make the hydraulic connection a Connect the tube Figure 3 to the water supply i...

Page 6: ...k system have been fixed to the chosen place you must connect the tube to the WATER STOP Antileak out let Figure 8 where it s marked OUT fully Once inserted place the security clip on it figure 9 g You must connect the other end of the tube to the ultrafiltration system Figure 1 where it s marked ENTRADA Inlet To do so you must unscrew the straight nut on the system s inlet Then insert the tube th...

Page 7: ...y and tightened b Make sure that the arm of the WATER STOP Antileak sys tem is down like shown in the figure so that the water can enter the ultrafiltration system c Open the water supply and then the ball valve fig ure 5 as shown Make sure there is no water leak If there is close the valve and fix it d Open the faucet Figure 2 and let all of the air out from inside the ultrafiltration system Once...

Page 8: ... and by authorized personnel that guarantees the quality of the water produced and the correct operation of the osmosis system the warranty will be void Cartridge type Antibacterial Sediments cartridge Carbon CTO cartridge Ultrafiltration membrane Nanosilver Carbon cartridge Stage 1st 2nd 3rd 4th Reference CA 1218 03 CA 0218 05 CA 0218 04 ME 0218 06 Appearance Replace 6 9 month 6 9 months 1 2 year...

Page 9: ...wnwards to remove it from its cap as indicated in the follow ing figure This process must be carried out for each of the cartridges that you want to replace d Remove the cartridges membrane from their original packaging Each cartridge and or membrane must be placed in the corresponding position maintaining the correct order To do so you must insert each cartridge in its cap and turn it anti clockw...

Page 10: ...eaks if there are any close the valves and fix them Precaution 1 If there is any water leak in any area of the tube connections remove it and cut off 0 5cm Then reconnect it If the leak s produced on any thread unscrew the piece apply more Teflon and screw it back on 6 2 PROCEDURE FOR REPLACING THE WATERSTOP ANTILEAK ABSOR BENT MATERIAL In the case of having to change the WATER STOP Antileak absor...

Page 11: ...e Check if the Antileak system has been activated If so find the leak and fix it change the absorbent material and lower the arm on the Antileak system 2 Plastic or syn thetic taste a Worn Nanosilver Carbon cartridge a Replace cartridge 5 Chlorine taste and smell a Worn cartridges a Change the cartridges 5 Unpleasant taste and smell b Contamination b Change the filters membrane post filter and san...

Page 12: ... OI 0230 24 Faucet 1 8 OI 0207 54 plastic insert 2 9 TU 0602 01 Tube 1 10 OI 0234 44 NELVA ultrafiltration support bracket 1 11 OI 0235 02 QC3 cartridge cups 4 12 OI 0208 16 M x T Straight 2 13 OI 0208 04 M x M Double Male connector 3 14 CA 0218 03 QC3 Antibacterial sediments cartridge 1 15 CA 0218 05 QC3 Carbon Block CTO cartridge 1 16 ME 0218 04 Ultrafiltration membrane 1 17 CA 0218 06 QC3 NANOS...

Page 13: ...embrane change Post filter change Sanitization Reparation Name and signature of the authorised technician or distributor DATE SERVICE MADE NEXT SERVICE OBSERVATIONS Sediments GAC y CTO cart change Membrane change Post filter change Sanitization Reparation Name and signature of the authorised technician or distributor DATE SERVICE MADE NEXT SERVICE OBSERVATIONS Sediments GAC y CTO cart change Membr...

Page 14: ...t filter change Sanitization Reparation Name and signature of the authorised technician or distributor DATE SERVICE MADE NEXT SERVICE OBSERVATIONS Sediments GAC y CTO cart change Membrane change Post filter change Sanitization Reparation Name and signature of the authorised technician or distributor DATE SERVICE MADE NEXT SERVICE OBSERVATIONS Sediments GAC y CTO cart change Membrane change Post fi...

Page 15: ...t filter change Sanitization Reparation Name and signature of the authorised technician or distributor DATE SERVICE MADE NEXT SERVICE OBSERVATIONS Sediments GAC y CTO cart change Membrane change Post filter change Sanitization Reparation Name and signature of the authorised technician or distributor DATE SERVICE MADE NEXT SERVICE OBSERVATIONS Sediments GAC y CTO cart change Membrane change Post fi...

Page 16: ...t filter change Sanitization Reparation Name and signature of the authorised technician or distributor DATE SERVICE MADE NEXT SERVICE OBSERVATIONS Sediments GAC y CTO cart change Membrane change Post filter change Sanitization Reparation Name and signature of the authorised technician or distributor DATE SERVICE MADE NEXT SERVICE OBSERVATIONS Sediments GAC y CTO cart change Membrane change Post fi...

Page 17: ...17 ...

Reviews: