USER'S GUIDE R10 AXIAL FAN , Code: 0000, Iss: 3.02.2020

03

OPERATING CONDITIONS

The fan is rated and designed for S1 (IEC 60034-1) continuous operation.

Extreme ON-OFF switching operating must be avoided, because it has negative influence on life expectancy and power consumption.

Cycling operating mode should only with cycling ON/OFF via control signal (0/10V analog input or PWM input).

Do not cycling the power supply for cycling operating mode – use control signal ! High 'In-rush current' can occur during cycling power supply!

Permissible ambient temperature is stated to the specified operating points. If actual load deviates from specified operating point, motor 
temperature-rise should be checked.

Figures on the motor name-plate refer to nominal values according to EN 60335 if not otherwise specified and inscribed on the nameplate (EN 
60335, 'free air', 'max.load', 'max.eff.',  cust. unit / cust. spec., UL, IEC 60034-1)

Continuous sound pressure level may exceed 70dBA (depends of fan model).

If an already installed fan is switched OFF for a long period in a humid atmosphere, it should be switched ON for minimum of two hours every 
month to remove any moisture that may have condensed inside the motor.

Protection (motor & electronics): IP54 according to EN60529 when it is installed in the customer's application. At least IP10 level of protection 
must be provided with application enclousure.

Power consumption in stand-by mode: les than 1.0W acc. to EN 50561.

 NOMINAL DATA - defined according to ' EN60335 '

Phase : 1~

Voltage : 230 V

Frequency : 50-60 Hz

Input power: 240 W

Nominal current : 1,68 A

Rotational speed : 950 RPM

Max. ambient temperature : 60 °C

Degree of protection provided by enclosures : IP54

Insulation class : 130

Min. ambient temperature : -25 °C

Max. pressure : 90 Pa

ErP DATA

Overall Efficiency , Effes : 50,8 %

Installation category : A

Efficiency category : static

Efficiency grade , N : 60,7

Variable speed drive : INTEGRATED

Power Input , Pelec: 276 W

Airflow volume , qV: 5304 m³/h

Pressure Increase, ps: 86 Pa

Rotational Speed, n : 960 RPM

Specific ratio : 1,001

Airflow volume max. , qV: 7804 m³/h

Pressure Increase max., ps: 195 Pa

1. Fan type and code
2. Trade mark and manufacturer address
3. Nominal values (Voltage, frequency, Electric Power, Current...)
4. Certification marks
5. Date of production (week of the year/year)
6. QR code which includes code number, production date, serial number and 
link to website.
7. Data acc. to EU regulation 327/2011 (ErP)
8. NOTE INDICATE TO WHICH STANDARD/RULES CORESPOND DATA ON THE 
NAMEPLATE:

- EN 60335-1 

: Name-plate data are made according to standard EN 60335-

1, Household and similar electrical appliances – Safety – Part 1, Articles 
10.1 and 10.2:
If an appliance is marked with rated power input, the power input at 
normal operating temperature shall not deviate from the rated power 
input by more than: + 20% if Pn<300W or  +15% (or 60W whichever is the 
greater)  if Pn>300W.
If an appliance is marked with rated current, the current at normal 
operating temperature shall not deviate from the rated current by more 
than: +20% if In<1.5A or  +15% (or 0,30A whichever is the greater)  if 
In>1.5A.

- FREE AIR

: Data on the nameplate established at a point 0Pa static 

pressure.

- MAX LOAD 

: Data on the nameplate established at a point of maximal 

static pressure regarding max. ambient 

temperature

.

- MAX. EFF. 

: Data on the nameplate established at a point of maximal 

static efficiency.

- CUST. UNIT / CUST. SPEC.

: Data on the nameplate specified according to 

customer specifications or at working point in customer's unit .

- UL

- Data on the nameplate defined according to specifications in UL 

standards.

- IEC 60034-1 

- Data on the nameplate established at a point of nominal 

load according to standard for Rotational electrical machines.

An example of a label and explanation of the content

:

1

2

5

6

7

8

3

4

© Copyright  HIDRIA d.o.o., All rights reserved. Document is subject to change without prior notification.

4 / 8

Summary of Contents for R10R-56LPS-ES50B-04C10

Page 1: ...06 PUTTING INTO OPERATION 07 MAINTENANCE SERVICE AND CLEANING 08 DIAGNOSTICS 09 PROTECTIVE FEATURES 10 EMC 11 TRANSPORT AND STORAGE 12 ErP AND ROHS DIRECTIVES 13 SERVICE ADDRESSES AND ADDITIONAL DATA...

Page 2: ...be safeguarded especially for the rotating parts Should there be a malfunction it must be ensured that the parts breaking off or flying away cannot cause serious damage or bodily harm Do not operate...

Page 3: ...s of water to axial fan from the rotor side This appliance is not intended to be built as a partition fan mounting in outside windows or walls unless it is built into an end application which is desig...

Page 4: ...tegory static Efficiency grade N 60 7 Variable speed drive INTEGRATED Power Input Pelec 276 W Airflow volume qV 5304 m h Pressure Increase ps 86 Pa Rotational Speed n 960 RPM Specific ratio 1 001 Airf...

Page 5: ...power supply and separated ordinary PVC cable eg H03VV F 5X 0 5 mm no longer than 2m outer diameter max 6 5mm for control circuit Fan performed with terminal box is as supplied fitted with a sealing...

Page 6: ...d for electromagnetic noisy environments PWM signal must be in square form with polarity the same as for linear voltage input see connection diagram PWM duty cycle 0 100 correspond to 0 10V linear vol...

Page 7: ...carefully to avoid damage to them Never use a high pressure cleaner or water spray for cleaning Wet cleaning under voltage may lead to an electric shock Do not use any aggressive paint solvent cleanin...

Page 8: ...connection cables When unpacking fans transported in such a way grip the fan to protection grill Do not apply any force for the cable s When transporting fans mounted on final units apparatus take ca...

Reviews: