USER'S GUIDE

FAN WITH ELECTRONICALLY COMMUTATED EXTERNAL-ROTOR MOTOR

Fan Code:

0310-4-0135

Fan type : R10R-56LPS-ES50B-04C10

&

Note :

Table of Contents :

01

SAFETY

02

TYPICAL FEATURES AND PROPER USE

03

OPERATING CONDITIONS

04

INSTALLATION AND CONNECTION

05

SPEED CONTROL

06

PUTTING INTO OPERATION

07

MAINTENANCE, SERVICE AND CLEANING

08

DIAGNOSTICS

09

PROTECTIVE FEATURES

10

EMC

11

TRANSPORT AND STORAGE

12

ErP AND ROHS DIRECTIVES

13

SERVICE ADDRESSES AND ADDITIONAL DATA

Be sure to familiarize yourself with these instructions before working on this unit. Not paying attention to these 
warnings and instructions may lead to malfunctions and failures or may seriously endanger human life.

Symbols :

- important values

- valuable information

Summary of Contents for R10R-56LPS-ES50B-04C10

Page 1: ...06 PUTTING INTO OPERATION 07 MAINTENANCE SERVICE AND CLEANING 08 DIAGNOSTICS 09 PROTECTIVE FEATURES 10 EMC 11 TRANSPORT AND STORAGE 12 ErP AND ROHS DIRECTIVES 13 SERVICE ADDRESSES AND ADDITIONAL DATA...

Page 2: ...be safeguarded especially for the rotating parts Should there be a malfunction it must be ensured that the parts breaking off or flying away cannot cause serious damage or bodily harm Do not operate...

Page 3: ...s of water to axial fan from the rotor side This appliance is not intended to be built as a partition fan mounting in outside windows or walls unless it is built into an end application which is desig...

Page 4: ...tegory static Efficiency grade N 60 7 Variable speed drive INTEGRATED Power Input Pelec 276 W Airflow volume qV 5304 m h Pressure Increase ps 86 Pa Rotational Speed n 960 RPM Specific ratio 1 001 Airf...

Page 5: ...power supply and separated ordinary PVC cable eg H03VV F 5X 0 5 mm no longer than 2m outer diameter max 6 5mm for control circuit Fan performed with terminal box is as supplied fitted with a sealing...

Page 6: ...d for electromagnetic noisy environments PWM signal must be in square form with polarity the same as for linear voltage input see connection diagram PWM duty cycle 0 100 correspond to 0 10V linear vol...

Page 7: ...carefully to avoid damage to them Never use a high pressure cleaner or water spray for cleaning Wet cleaning under voltage may lead to an electric shock Do not use any aggressive paint solvent cleanin...

Page 8: ...connection cables When unpacking fans transported in such a way grip the fan to protection grill Do not apply any force for the cable s When transporting fans mounted on final units apparatus take ca...