background image

HID Signo™ Reader Installation Guide

August 2020

PLT-03704, Rev. A.3

3

Powering

Trusted Identities

2

 Wire the reader

Pigtail version

Terminal Strip version

PIGTAIL

TERMINAL DESCRIPTION

Red

1

+VDC

Black

2

Ground (RTN)

White

3

Wiegand Data 1 / Clock / RS485-A*

Green

4

Wiegand Data 0 / Data / RS485-B*

Orange

5

LED Input (GRN)

Yellow

6

Beeper Input

Blue

7

Hold Input / LED Input (BLUE)*

Brown

8

LED Input (RED)

Violet/White

9

Tamper 2 (RLY2)

Violet

10

Tamper 1 (RLY1)

Bare

Drain (pigtail models only)

*Dependent upon reader configuration

Note:

 Wiring the reader incorrectly may permanently damage the reader.

Note:

 Previous iCLASS® readers had reversed RS-485 wiring (P2-7 & P2-6 - A & B). When upgrading to a HID Signo 

reader, ensure proper connections as defined above.

Note:

 Data 0 and Data 1 wires for Wiegand may be reused for OSDP. However, standard Wiegand cable may not meet 

RS485 twisted pair recommendations.

Note:

 For OSDP cable lengths greater than 200 ft (61 m) or EMF interference, install 120

 +/- 2

 resistor across RS-

485 termination ends.

Note:

 For keypad configuration, with the keypad reader operating as 26 bit emulation, enter the facility code followed 

by # within five seconds of power-up. The facility code must be entered as three digits (i.e., for a facility code of 10 

enter 0-1-0-#). If unsuccessful, the reader LED displays solid red. Power-cycle the reader and retry entering the facility 

code.
HID Signo readers use facility codes between 1-255, and no default is set. Once a facility code is entered, the reader 

LED displays violet, then solid red. Then, power-cycle the reader. If there are two short beeps after entering a PIN, the 

reader facility code is not configured. In this case, power-cycle the reader and retry entering the facility code.

18" (0.46m)