PARTS LIST (Included) 

Quantity

- ProxPoint™ Reader with snap-on 
cover and 18” cable 

 

- #4-24 x 1” self-tapping flathead screw 

- Installation manual 

 

PARTS LIST (Not-Included) 

Quantity

- Wire splice 

- DC Power supply 5.1 VDC or 12 VDC 

 

Mounting Instructions 

 

  Determine an appropriate mounting location. The reader 

may be mounted to any surface, including metal. 

  Drill two (2) 5/64-inch (2mm) holes approximately 1 inch 

deep for mounting the reader. 

  Drill a 5/8-inch (16mm) hole for the cable. 

  Remove the snap-on cover from the reader and secure 

the reader to the mounting surface. 

  Route the cable from the reader and/or power supply to 

the host. A linear type power supply is recommended. 
Check all electrical codes for proper cable installation. 

  Test the operation of the reader. After completion of the 

test, replace the snap-on cover. 

  For proper regulatory compliance, the drain wire should 

be disconnected at the power supply end of the cable. 

  Changes or modifications not expressly approved by the 

party responsible for compliance could void the user’s 
authority to operate the equipment. 

  The Reader is intended to be powered from a limited 

power source output of a previously certified power 
supply. 

 

In cold climates (-20

°

F), when operating the Reader from 

a 5V power supply, limit the cable distance to 200ft. For 
longer cable distances, 12V is required.

 

 

 

Connecting the Reader to the Host 

 
Connect the reader to the host according to the wiring 
table below and the host installation guide. 
 

Wiegand 

Clock & Data 

Wire Color 

+DC +DC Red 

Ground Ground  Black 

--- Card 

Present 

Violet 

Data0 Data Green 
Data1 Clock White 

Shield Ground 

Shield Ground 

Drain 

Green LED 

Green LED 

Orange 

Red LED 

Red LED 

Brown 

Beeper Beeper  Yellow 

Hold  

Hold 

Blue 

 

Testing and Operation 

 

  When power is applied to the reader the LED will 

flash green three (3) times while the beeper beeps 
simultaneously. The LED will then turn red. This 
indicates that the microcontroller is operating 
properly. 

  Present an ID card to the reader. The LED will 

momentarily turn green while the beeper beeps 
once, indicating that the card was read 
successfully. 

 

Important Product Specifications 

 

Power requirements (linear supply) 

Operating Voltage Range            5.1 – 16.0 VDC 
Peak Current                               80 Ma 
Average Current 5V or 12V         20 Ma 
Maximum cable distance             500 ft (153 m) 
To host 
Maximum cable distance             200 ft (61 m) 
To host @5V  

 
 

FCC Compliance Statement:

 This device complies 

with part 15 of the FCC rules. Operation is subject to 
the following two conditions: (1) this device may not 
cause harmful interference, and (2) this device must 
accept any interference received, including 
interference that may cause undesired operation. 

 

 