background image

INSTALLATION GUIDE

hidglobal.com

An ASSA ABLOY Group brand

© 2012 - 2018 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID GLOBAL, HID, the HID Brick logo, the Chain Design, and PIVCLASS are trademarks or registered 

trademarks of HID Global, ASSA ABLOY AB, or its affiliate(s) in the U.S. and other countries and may not be used without permission. All other trademarks, service marks, and 

product or service names are trademarks or registered trademarks of their respective owners. 

This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output 

are fictitious. Specifications are subject to change without notice.

pivCLASS

  R10-H, RP10-H, R40-H, RP40-H, RK40-H, RPK40-H, RKCL40-P, 

RPKCL40-P, RKCLB40-P

Wiring

Pigtail

Terminal

Description

Pigtail 

Terminal

Description

Yellow

P1-1

Beeper Input

Red / Green

P2-7

*GPIO1/OSDP (RS485-FDX/HDX-A) 

Orange

P1-2

LED Input (GRN)

Tan

P2-6

*GPIO2/OSDP (RS485-FDX/HDX-B)  

Black

P1-3

Ground (RTN)

Violet

P2-5

**Open Collector Output / Tamper  

Red

P1-4

+VDC

White

P2-4

***Wiegand Data 1 / Clock  

                 

Drain

P1-5

Unused

Green

P2-3

***Wiegand Data 0 / Data 

                 

Brown

P1-6

LED Input (RED)

Pink

P2-2

*GPIO3 (RS485-FDX-Z) 

                 

Blue

P1-7

Hold Input

Gray

P2-1

*GPIO4 (RS485-FDX-Y) 

                 

*RS-485 applicable for pivCLASS readers.

**Tamper Output - When activated, output synchronizes to ground (default).
***Dependent upon reader configuration. See the HTOG for Wiegand and Clock-in-Data configurations.

ATTENTION

Observe precautions for handling

ELECTROSTATIC SENSITIVE DEVICES

P1
P2

Beeper

GRN LE

D

GN

D

+VDC

DRAIN

RE

D

HOLD

GPIO

1

GP10

2

OC/TMP

R

DATA
1/CL
K

DATA
2/D

ATA

GPIO

3

GPIO

4

Beeper

GRN LED

GND

+VDC

DRAIN

RED

HOLD

GPIO1

GP102

OC/TMPR

DATA1/CLK

DATA2/DATA

GPIO3

GPIO4

18 in

(0.46 m)

BEEP (YEL)

GRN LED (ORN)

GND (BLK)

+VDC (RED)

DRAIN (BARE)

RED LED (BRN)

HOLD (BLU)

GPIO1(RED/GRN)

GPIO2  (TAN)

OC/TMPR (VIO)

DATA1 (WHT)

DATA2 (GRN)

GPIO3 (PINK)

GPIO4 (GRAY)

Terminal Reader

Pigtail  Reader

(Terminal block and module 

position varies)

(Module position varies)

Notes:

1. Previous iCLASS readers had reversed RS-485 wiring 

    (P2-7 & P2-6 - A & B). When upgrading to a pivCLASS

    reader, ensure proper connections as defined below.
2. Wiring the reader incorrectly may permanently damage 

    the reader.
3. For cable lengths greater than 200 ft. (61 m) or EMF

    interference, install 120Ω +/- 2Ω resistor across 

    RS-485 termination ends.
4. It is possible to reuse existing Wiegand wiring for 

    OSDP, however, using simple stranded cable (typical of 

    Wiegand access control readers) usually does not meet 

    RS-485 twisted pair recommendations.

Summary of Contents for pivCLASS R10-H

Page 1: ...Order Guide Security tool for spanner security screw anti tamper HID 04 0001 03 Specifications pivCLASS Protocol PRODUCT BASE PART NUMBER INPUT VOLTAGE VDC CURRENT OPERATING TEMPERATURE CABLE LENGTH U...

Page 2: ...ndby AVG2 Maximum AVG3 PEAK4 R10 H 900N 5 16VDC 12VDC for RS 485 60mA 100mA 200mA 30 to 150 F 35 to 65 C Communication Lines Wiegand 500 ft 22 AWG 152 m 300 ft 24 AWG 91 m RS 485 Max bus length 4000 f...

Page 3: ...rown P1 6 LED Input RED Pink P2 2 GPIO3 RS485 FDX Z Blue P1 7 Hold Input Gray P2 1 GPIO4 RS485 FDX Y RS 485 applicable for pivCLASS readers Tamper Output When activated output synchronizes to ground d...

Page 4: ...names are trademarks or registered trademarks of their respective owners This Installation Guide is for informational purposes only HID makes no warranties expressed or implied in this summary Company...

Page 5: ...40 H RP40 H RK40 H RPK40 H RKCL40 P RPKCL40 P RKCLB40 P 4 Power Testing Contactless Models Contact Models Turn on power Test card Note With a keypad reader operating as 26 bit emulation upon power up...

Page 6: ...in this summary Company product names and data used in sample output are fictitious Specifications are subject to change without notice pivCLASS R10 H RP10 H R40 H RP40 H RK40 H RPK40 H RKCL40 P RPKCL...

Page 7: ...the left side of the assembly 1 Disassemble the reader Remove the Keypad reader from the backplate Carefully unplug the ribbon cable from the module in the back of the Keypad reader Caution Do not pu...

Page 8: ...ith the M2000 pivCLASS Authentication Module as well as Standard Wiegand and OSDP panels FCC Certification CAUTION Any changes or modi cations to this device not explicitly approved by manufacturer co...

Reviews: