INSTALLATION GUIDE
hidglobal.com
An ASSA ABLOY Group brand
GOVERNMENT SOLUTIONS for Physical Access
R10-H, RP10-H, R40-H, RP40-H, RK40-H,
RPK40-H, RKCL40-P, RPKCL40-P, RKCLB40-P
pivCLASS® Reader
Parts
1 - Reader and base plate assembly
1 - Installation guide
2 - Terminal connector - terminal readers only
RKCL40, RPKCL40 & RKCLB40
4 - M3.5 mm x 12 mm Phillips machine screw
4 - #6-32 x .375” Phillips self-tapping machine screw
4 - #6 x 1.5” Phillips sheet metal screw
3 - #6-32 x .4375” Spanner security screw, anti-tamper (black)
3 - #6-32 x .4375 Phillips security screw (black)
1 - Mounting gasket
Recommended
• Cable, 6 conductor, 22 or 24 AWG [65 mm or 51 mm] Twisted Pair, Over-All Shield (Belden 3108A or equivalent) - RS-485-FDX +
power
• Cable, 4 conductor, 22 or 24 AWG [65 mm or 51 mm] Twisted Pair, Over-All Shield and UL approved (Belden 3107A, or equivalent) -
RS-485-HDX + power
• Cable, 6 to 9 conductor, 22 or 24 AWG [65 mm or 51 mm] Over-All Shield, (Alpha 1296C or equivalent) - W power
• DC power supply
• Metal or plastic double-gang junction box -
RPKCL40 / RPKCL40 / RKCLB40
• Metal or plastic single-gang junction box -
R10 / RP10 / R40 / RP40 / RK40 / RPK40
• Reader spacer when using metal junction boxes - see pivCLASS How to Order Guide
• Security tool (for spanner security screw, anti-tamper) HID 04-0001-03
Specifications
pivCLASS Protocol
PRODUCT
BASE PART
NUMBER
INPUT VOLTAGE
(VDC)
CURRENT
OPERATING
TEMPERATURE
CABLE LENGTH
UL REF
NUMBER
Standby
AVG
1
Maximum
AVG
2
PEAK
3
R10-H
900NHR
12VDC
60mA
100mA
200mA
-30° to 150° F
(-35° to 65° C)
RS-485
= 500 ft - 22 AWG
(152 m)
300 ft - 24 AWG
(91 m)
R10E
x
1
x
2
x
3
RP10-H
900PHR
75mA
RP10E
x
1
x
2
x
3
R40-H
920NHR
65mA
110mA
R40E
x
1
x
2
x
3
RP40-H
920PHR
85mA
RP40E
x
1
x
2
x
3
RK40-H
921NHR
85mA
125mA
220mA
RK40E
x
1
x
2
x
3
RPK40-H
921PHR
95mA
RPK40E
x
1
x
2
x
3
RKCL40-P
923NPR
150mA
185mA
250mA
-4° to 122° F
(-20° to 50° C)
RKCL40E
x
1
x
2
x
3
RPKCL40-P
923PPR
RPKCL40E
x
1
x
2
x
3
RKCLB40-P
924NPR
165mA
215mA
275mA
14° to 122° F
(-10° to 50° C)
RKCLB40E
x
1
x
2
x
3
R10, RP10, R40, RK40, RP40 & RPK40
2 - M3.5 mm x 12 mm Phillips machine screw
3 - #6-32 x .375” Phillips self-tapping machine screw
2 - #6 x 1.5” Phillips sheet metal screw
1 - #6-32 x .375” Spanner security screw, anti-tamper
1 - Mounting gasket (optional, recommended for outdoor
installation)
1
Standby AVG - RMS current draw without a card in the RF field.
2
Maximum AVG - RMS current draw during continuous PIV card reads. Not evaluated by UL.
3
Peak - highest instantaneous current draw during RF communication.
UL Reference Number Deciphering
x
1
Reader Colors:
K = Black
x
2
Wiring:
N = Pigtail,
T = Terminal
x
3
Communications: N = No Module, R = RS-485
PLT-01134 A.8