Fitting 

1. 

Choose a suitable position for your fan 
according to Figure 1 opposite. Use a 
cable finder to check if there are any 
buried cables or pipes in the ceiling. 
Ceiling mounted ventilation should 
be ducted through the roof space, by 
ducting to an external soffi t under the 
eaves or grille in the slope of your roof. 

NB: Ducting installed between a floor and 
ceiling can only run between joists, not 
across them. 

2.  Mark the position of the vent fascia with a 

pencil in a suitable position on the ceiling, 
making sure that it is between the joists. 

3.  Drill a 9mm hole through the ceiling 

anywhere along the edge of the pencil 
line. Now cut out the hole with a pad saw. 

4.  Hold the vent fascia against the ceiling 

and mark the position of the fixing holes. 
Fix the unit in place using suitable heavy 
duty plasterboard fixings (not supplied). 

5.  Attach flexible ducting (not supplied) with 

the metal hose clamps. Ensure that the 
ducting has a smooth flow towards the 
external grille to minimise air resistance. 
Follow a similar procedure for the outside 
wall grille.

Casing

Terminal block

Lamp terminal block

Lamp socket

Hole for power wires

Holes for fan mounting

Electrical Connection

1. 

Ensure the domestic electrical mains 
supply to which the fan is being 
connected is turned off. This product 
is designed to be connected to an on/
off switch outside the bathroom, or to a 
ceiling mounted pull cord switch.Ensure 
the domestic electrical mains supply 
to which the fan is being connected is 
turned off. This product is designed to be 
connected to an on/off switch outside the 
bathroom, or to a ceiling mounted pull 
cord switch.

2.  Remove the protecting grille and lamp. 

This product is SELV and the mains power 
should be connected to the transformer 
supplied. See diagram below. 

Summary of Contents for Air-Star Series

Page 1: ...ing installation to ensure that your product is fitted safely and that it retains its high quality finish Please retain this leaflet for future reference Before drilling ensure there are no hidden cables or pipes in the wall Please see Fig 1 on the back page for details Suitable for installation in zones 2 Outside Zones Air Star Silver Art no 32100 Air Star White Art no 31900 ...

Page 2: ...able heavy duty plasterboard fixings not supplied 5 Attach flexible ducting not supplied with the metal hose clamps Ensure that the ducting has a smooth flow towards the external grille to minimise air resistance Follow a similar procedure for the outside wall grille 1 Casing 2 Terminal block 3 Lamp terminal block 4 Lamp socket 5 Hole for power wires 6 Holes for fan mounting Electrical Connection ...

Page 3: ...his fan Do not replace with any other bulb as this will invalidate any warranty Do not exceed the stated wattage Maintenance In the event of a fault please check the in line fuse located inside the connection box Fan maintenance is to be performed only after the fan is disconnected from the mains power supply Maintenance means periodic clearing of the surfaces from dust and dirt In order to remove...

Page 4: ...try and make sure they are as accurate as possible In the interest of continuous product development HiB reserves the right to alter specifications as necessary E OE T 44 0 20 8441 0352 F 44 0 20 8441 0219 E sales hib co uk hib co uk Building 3 North London Business Park Oakleigh Road South New Southgate London N11 1GN Fig 1 Electrical Safety Information Ensure mains power supply is switched off b...

Reviews: