Here need to setup only based on linking network. Operations: ENT + press 

” button to delete old  X X X X + 

ENT

 

→ “X X X X”: 4 digits, you can set 0000~9999. Default set before shipping is at ransom.   

Upload status

】:

   

This is for uploading Arm/Disarm/Alarm information to the Managing Centre. Operations:

ENT + “▲▼” + ENT

 

→ “▲▼” 

choose “yes” or “no” for upload or not upload. The defaulted is “No”.   

CutWire Alarm

】:

 

  This is for PSTN (landline) only. ENT + CutWire Alarm, press 

“▲▼” to choose YES or NO. If choose “Yes”,it will alarm when   

telephone line is not connected. Default set before shipping is 

“Yes”. 

Zone Attribute

】:

 

Here is for setting

Zone number

,

Zone type

Alarm Type

】【

Bypass Zone

  &

Entry Delay Set?

---

Zone number

】:

 

Here has 39 zonesfor your settings. 2 dedicated zones for remotes(Supports up to 4 remotes or wireless keypads per zone).29 

wireless zones(Each zone supports up to 4 sensors) and 8 optional wired zones. Each zone needs to setup 

“Zone Type”, “Alarm 

Type

” ,“Bypass Zone” & “Entry Delay”.   

Table 3:   

“Zones Number” setting 

Zone 

Number 

Sensor Type   

Zone 

Type 

Applicable sensor names 

Notes 

00

01 

Wireless sensors

 

——

 

Wireless remote & Wireless Keypad 

Each zone 

support up to 4 

sensors 

02 ~ 10 

Emergency  zone 

Wireless Smoke Alarm, 

Wireless Gas Alarm& Panic button etc. 

11 ~ 20 

Perimeter zone 

Wireless Door/Window Sensor & 

Wireless Curtain PIR etc. 

21 ~ 30 

Motion zone 

Wireless Wide-Angle PIR Motion Sensor etc. 

31 ~ 38 

Wired sensor

 

——

 

31,32,33 are Perimeter zone 

34,35 are Motion zone 

36,37,38 are Emergency zone 

See Table 4: 

Wireless/wired 

sensor code

 

Zone Type

】:

   

You can see 

“2”, “1”, “0”.( “2” mean motion zone, “1” means perimeter zone, “0” means emergency zone) 

Press 

“▲▼” to choose the one you desire to setup, then press ENT to confirm your settings. 

Alarm Type

】:

   

ENT + Alarm Type+ press 

” button to delete old  X X + ENT

→ “X X”: 2 digits. Alarm type code. 2 digits.( See 

below table. ) 

Table 4: Wireless/wired sensor code 

 

 

 

 

 
 

 

 

 

Table 5:    Default set before shipment 

Wireless sensors 

Wireless 

remote 

Wireless door 

sensor 

Wireless 

wide-angle 

PIR sensor 

Wireless gas 

sensor 

Wireless 

smoke sensor 

Zone Number 

00 

11 

21 

02 

03 

 

Bypass Zone

】:

 

This setting is for make zones enable or disable. Here has 

“Yes” & “No” for your alternatives. “Yes” means make this zone‟s 

sensors silent, 

“No” means keep this zone‟s sensors working. Press “▲▼” to choose “Yes” or “No”, then press ENT to confirm 

your settings.   

Entry Delay Set?

】:

 

Code 

00 

01 

02 

03 

04 

05 

06 

07 

Sensor 

Name 

Button0 

Button1 

Gas 

Smoke 

Door 

Window 

Glass 

Motion 

Code 

08 

09 

10 

11 

12 

13 

14 

15 

20 

Sensor 

Name   

IR 

Perimeter 

Perimeter 

Motion 

Sensor 

Sensor 

Sensor 

Sensor  (doorbell) 

Summary of Contents for GSM+PSTN Touch Screen Wireless Alarm System

Page 1: ...eless zones Each zone supports up to 4 sensors and 2 dedicated zones for remotes Supports up to 4 remotes or wireless keypads per zone Sipports 8 more wired zones Optional 5 Can preset up to 5 phone numbers and dial in sequence 6 Intelligent logic analysis technology corresponding zone number and sensor name can be displayed 7 Record up to a 10 second greeting for the auto dialer Then play the gre...

Page 2: ...lt in Li Ion backup battery 3 7V 800mAH rechargeable Standby around 16 hours Full charging time 12 hours 2 Band GSM GSM900 1800Mhz 4 Band is optional 850 900 1800 1900Mhz GSM transmit power 2W Receiving and emitting frequency 433MHz Working condition Temperature 10º C 50º C Humidity 80 Product dimension 150 107 26 mm 2 Zone types and definitions Zone types Perimeter zone Motion zone Emergency zone...

Page 3: ...ps flash about every 2 seconds Signal indicator keeps on 4 Band 850 900 1800 900 MHZ Signal indicator keeps flash about every 3 seconds Signal indicator keeps flash about every 1 seconds Signal level status When standby press or and you can see the signal status as below XX 0 31 indicates the signal from weak to strong 99 indicates unknown YY Indicates signal status OK is good No is a little weak ...

Page 4: ...day 0 means Sunday Auto Dialer s Totally 5 telephone mobile numbers The first group is fixed for management center other 4 groups are fixed for personal numbers Press to select the report method SMS Phone No for voice alarming SMS reporting for SMS text alarming Notes if you choose SMS Reporting it will just sent to mobile numbers not include PSTN landline phone numbers Press ENT to confirm each p...

Page 5: ... zone Wireless Smoke Alarm Wireless Gas Alarm Panic button etc 11 20 Perimeter zone Wireless Door Window Sensor Wireless Curtain PIR etc 21 30 Motion zone Wireless Wide Angle PIR Motion Sensor etc 31 38 Wired sensor 31 32 33 are Perimeter zone 34 35 are Motion zone 36 37 38 are Emergency zone See Table 4 Wireless wired sensor code Zone Type You can see 2 1 0 2 mean motion zone 1 means perimeter zo...

Page 6: ...n the LCD Screen Note If a word update shows on the screen which means this sensor has been added before you may choose Yes or No to decide going on programming or not for this sensor If choose Delete Sensor This means deleting the added sensors from the host Operations Get into the Program Sensor menu choose Zone Number and Group Number you desire to delete press to choose Delete Sensor press ENT...

Page 7: ...ng this SMS and also will message back to mobile Disarm successfully 12 Monitoring of door window status When the smart zone is ON the arm operation is normal if all the doors or windows are closed But if any door or window is open the host will sounds Di Di Di and at the same time it has below displays alternately XX zone number YYYYY sensor name Note 1 This function is available only with wirele...

Page 8: ...sensors in Perimeter Zone door sensor curtain PIR sensor and sensors in Emergency Zone Like Gas sensor Smoke sensor Glass sensor Emergency button it is not effective all sensors in Motion zone Like wide angle PIR Please replace the batteries after one year usage and when you feel shorter control distance How to program Please refer to the descriptions of Program Sensor or Table 6 Note You can only...

Page 9: ...nters into etecting area the sensor will transmit alarm signals to the alarm host Specifications Operating power 9V alkaline battery Emitting distance 100m in open area Service life 1 year Detecting distance 110 10 10m Installation and Usage Fix the bracket on suitable wall surface or in wall corner at a distance of 2 2 4m above the ground Open the sensor shell to connect the batteries well and ad...

Page 10: ...e added for each alarm host C Understanding of Optional Accessories Wireless Wireless Gas Alarm Features Mainly monitor and control indoor gas leak generally set as Emergency Zone Usually installed in kitchen Specifications Operating power 110 240VAC 50 60HZ Emitting distance 100m in open area Inductive gas Natural gas 0 1 0 5 Liquefied petroleum gas LPG 0 1 0 3 Installation and Usage Fix the gas ...

Page 11: ...to the alarm host according to the instruction below Unplug from the AC power fix it in the proper outdoor place with handing hook and then plug to the AC power The max time for alarming sound with flash is 3 minutes it will stop automatically after the alarm host is disarmed When the back up battery has a lower voltage than 5VDC the charging indicator turns on the back up accumulators will be cha...

Page 12: ... ENT Delete sensor ENT 2 The alarm host will beep once and press ESC to exit Door Sensor 11 20 4 1 Same as above 2 Trigger the door sensor twice successively Same as above Wide Angle PIR Sensor 21 30 4 1 Same as above 2 Trigger the PIR sensor by pressing Learning Emitting Switch on the panel twice successively Same as above Indoor siren N A 1 After connecting to the power press the learning switch...

Page 13: ...orter it s normal The host does not alarm after the new added wireless detector is triggered Failed to follow the operation instruction of Adding and deleting sensors to add the new wireless sensor Follow the operation instruction of How to program to activate the new wireless sensor The PIR sensor flashes frequently in green Batteries are running out Replace with new batteries of the same specifi...

Reviews: