background image

 

3

Introduction

 

 

Thank you for purchasing the ZOpid HB-ZA310V Automatic 
Blood Pressure Monitor. 
 

For your safety, please be sure to read this Instruction 
Manual thoroughly before using the Blood Pressure 
Monitor. For other specific information about your own 
blood pressure, CONTACT YOUR PHYSICIAN. 

 

 Measures Blood Pressure (SYS. & DIA.) & Pulse. 

  Fuzzy logic measurement system with fully automatic 

inflation and deflation to provide home blood pressure 
monitoring convenience. 

  Voice prompt function announces measured values.   

  80 sets of memory with Date/Time   

  Easy to wrap arm cuff suitable for arm sizes 8.7” to 

12.6” (Large cuff sold separately fits arms 12.6” to 16.6” 
in circumference)   

  Automatic turn-off after 1 minute. 

  Low Battery icon and intelligent error detection. 

  Operates on four “AA” alkaline batteries. 

  Recall and Scan functions. 

 

  Delete single or all measurements.

 

 
 

Warning Signs & Safety Statements

 

 

ATTENTION!! 
Read instruction manual before use. 

 

Type BF applied part   

 

                   

Double insulated 

 

Summary of Contents for HB-ZA310V

Page 1: ...Instruction Manual Automatic Blood Pressure Monitor for Arm Voice Prompt Function Announces Measured Values HB ZA310V ...

Page 2: ...on of Control Buttons 10 Description of LCD Display Symbols 10 Replacing Batteries 11 Voice Prompt Function 13 Set the Language of Voice Prompt 13 Program Date and Time 14 How to Apply the Arm Cuff 15 Correct Measurement Position 16 How to Take A Measurement 17 How to Use the Memory Features 19 How to Delete Single or All Memories 20 Maintenance 21 Error Message and Troubleshooting 22 Specificatio...

Page 3: ...c inflation and deflation to provide home blood pressure monitoring convenience Voice prompt function announces measured values 80 sets of memory with Date Time Easy to wrap arm cuff suitable for arm sizes 8 7 to 12 6 Large cuff sold separately fits arms 12 6 to 16 6 in circumference Automatic turn off after 1 minute Low Battery icon and intelligent error detection Operates on four AA alkaline bat...

Page 4: ...daily health management What is Blood Pressure Blood is pumped to artery by the beat contraction and expansion of a pump called the heart The pressure of the pumped out blood is called the blood pressure Blood pressure heaves with each beat of the heart The raised pressure when the heart contract is called the systolic blood pressure and the lowered pressure when the heart expands are called the d...

Page 5: ...e over a whole day with measurement taken every five minutes as shown below Classification of Blood Pressure by the WHO The World Health Organization WHO and the Inter national Society of Hypertension ISH developed the Blood Pressure Classification shown as below ...

Page 6: ...e accurately reflects your actual blood pressure Blood pressure fluctuates even by 30 to 50 mmHg depending on whether you are nervous or relaxed exercise or the environment temperature or mental state without being noticed The device may show some reading error in the presence of common arrhythmia such as arterial or ventricular premature beats or arterial fibrillation Precautions This unit will n...

Page 7: ... effect but generally blood pressure values at the wrist and upper arm should display the same pattern of change Consequently it is possible to monitor trends in change by measuring blood pressure at the wrist Contraindications Do not use the device on infants and persons who cannot express his her own will which may lead to serious accidents Do not use the device for purposes other than measuring...

Page 8: ...the device may damage the device by battery leakage Please read the Installing Replacing Batteries section in this manual The device might not meet its normal performance if stored or used beyond the temperature and humidity ranges specified below Operating conditions 10 40 40 85 R H Conditions for storage 20 50 15 85 R H Suggestions before Measuring Blood Pressure 1 Please relax yourself physical...

Page 9: ...easurement 8 Keep the records for your physician as reference Reminded that one measurement can t conclude the health of your blood pressure only recording long term measuring results will reveal the long term trend of your blood pressure Try to measure your blood pressure at the same time each day for consistency Device Description ...

Page 10: ... pulse To set the language of voice prompt or voice on off TIME To set the Date Time MEMO To review the measured record s by manual To select the digit of the Date Time SCAN Automatically review all previously memorized record s To select the digit of Date Time To delete memorized record s Description of LCD Display Symbols ...

Page 11: ...Date Time setting will be erased Then you must reset the Date Time 1 Slide the battery compartment to remove it 2 Place the batteries 4 AA Alkaline batteries in the compartment as indicated by the polarity symbols and marked inside All the display symbols appear for 1 seconds and then return to standby mode 3 Replace the battery compartment cover Note When Low Battery indicator appears on the disp...

Page 12: ...DO NOT mix using old and new or different type of batteries together d Remove the batteries if not using the blood pressure monitor for an extended period i e 3 months The batteries can leak chemicals then damage the electronic parts e Immediately replace run down batteries with new ones f Check the batteries periodically and replace them when necessary g When using the adapter alone without batte...

Page 13: ...prompt English Deutsche French Espanol can be set Make sure you have turned off the unit before you want to set the voice prompt function 1 Press START button the unit will show Eng 1 default and speak a demo voice in English Memory number 3 Systolic pressure 160 high Diastolic pressure 66 normal Pulse rate 62 2 Press MEMO button or SCAN button to set the number representing the language 3 Press S...

Page 14: ...n for 2 seconds until 2007 shown on the screen and starts to flash 2 Press MEMO button or SCAN button to set the number representing the Year 3 You can press and hold MEMO or SCAN buttons for about 2 seconds the number of the Year will be displayed in the faster speed 4 Press TIME button to confirm the Year setting Then the number representing the Date will flash ...

Page 15: ... 2 The cuff should be assembled correctly when it is removed from the box If it is not pass the end of the cuff furthest from the tubing through the metal D ring to form a loop The smooth cloth should be on the inside of the cuff loop 3 If the cuff is assembled correctly the sewn hook material will be on the outside of the cuff loop and the metal D ring will not touch your skin 4 Put your left arm...

Page 16: ...irmly against the pile side of the cuff 7 The cuff should be wrapped so that it fits snugly and stays in place You should be able to fit one finger between the cuff and your arm Correct Measurement Position It is extremely important for accurate measurements that the cuff is at the heart level Higher or lower position will give deviations from the true value ...

Page 17: ...nd follow directions in the section Suggestions before Measuring Blood Pressure and How to Apply the Arm Cuff before taking a measurement 1 Press POWER button to turn on the unit All the symbols displayed for a couple seconds then the number 0 The unit says measurement ready 2 Press START button the cuff automatically inflates to approximately 170mmHg 50mmHg higher than the average systolic blood ...

Page 18: ...ps flashing and your blood pressure and pulse will appear on the display In the mean time the unit announces the measured value of Systolic Diastolic and Pulse twice After taking the measurement the latest measured readings will always be displayed before the power is turned off Note Wait for at least 3 minutes if you want to take another measurement Waiting allows your blood vessels to bounce bac...

Page 19: ...ss MEMO button again to review the measurement from the latest to the earliest with voice prompt The latest measurement M 01 appears when you press MEMO button M 01 is the latest reading measured The Systolic Diastolic Pulse and Date Time of the measurement will be displayed Press MEMO button to repeatedly review other memorized readings The readings will be displayed as M 02 M 03 M 04 etc You can...

Page 20: ... You can delete the single memory just after taking the measurement Press SCAN button then dEL will appear and flash and says delete Press SCAN button again to confirm the delete function 2 Delete all measurements Turned off the unit first then press and hold SCAN button until dEL ALL displayed and says delete all Press SCAN button again and all memories will be deleted when 00 ALL shown on the sc...

Page 21: ...ene gasoline or solvent agent to clean the device 2 Wipe with a moistened cloth with clean water or a mild cleaning agent and then dry the device with a soft and dry cloth 3 The dirt on the cuff can be wiped by the moistened cloth and soap 4 Do not flush the device and cuff 5 Do not bend the cuff or sleeve and wrap the sleeve to the inside out surface 6 Do not disassemble the device or dismantle t...

Page 22: ... to correct Incorrect posture in measurement or the user moves or talks during measurement There are any artificial interference and noise during measurement User is tense and does not relax or has severe heart beat problem Cuff is not fastened well please fasten again by following the instructions Wait at least 3 minutes before taking another measurement Repeat steps listed under How to Take a Me...

Page 23: ... Insufficient or failure inflation Cuff broken Cuff is not fastened well please re fasten the cuff by following the instructions Pump or venting valve or deflation valve failure please contact the distributor If a trouble occurs while you are using the blood pressure monitor check the attached Troubleshooting first If you can not measure your blood pressure correctly even after taking the followin...

Page 24: ...ery polarities Remove the old batteries and wait for one minute then install the new batteries The inflation cannot be done or the air pressure cannot rise Cuff is not wrapped properly Check the arm position and fasten the cuff correctly and re measure the pressure again Battery low Battery voltage is excessively low In order to keep the previous measurements date time ensure the unit is turned of...

Page 25: ...roblem and the blood pressure reading may not be correct Under normal operating circumstance the reading at home is different from that of the clinics Usually people feel tenser in the hospital or clinic white robe effect than in their home Record the results and consult with your physician Each measurement has various reading The variation might be due to the different environments The blood pres...

Page 26: ... Release Automatic exhaust valve Sensor Semiconductor pressure sensor Power Supply 4 AA alkaline batteries Measuring Interval 1 mmHg Operating Temperature Humidity 10 40 50 0 F 104 0 F 40 85 R H maximum Storage Temperature Humidity 20 50 4 0 F 122 0 F 15 85 R H maximum Battery Life Alkaline batteries Approx 250 uses Unit Weight Approx 400grams not including batteries Cuff Circumference Fits arm ci...

Page 27: ...27 PERSONAL BLOOD PRESSURE S RECORD Name _________ Age ________ Weight _________ Date Time SYS DIA PULSE Remark ...

Page 28: ...28 Conformity Standards Medical device electrical safety EN 60601 1 Electromagnetic Compatibility EN 60601 1 2 EN 1060 1 EN 1060 3 Performance Standard ANSA AAMI SP10 FDA 510K ...

Page 29: ...excluded from coverage Miscellaneous This warranty does NOT cover defects or damage that result from a Improper operation storage misuse or abuse accident or neglect such as physical damage cracks scratches etc to the surface of the Product resulting from misuse b Contact with liquid water rain extreme humidity or heavy perspiration sand dirt or the like extreme heat or food c Use of the Product f...

Page 30: ...A Inc The information contained in this User Manual is believed to be correct at the time of printing HiTT reserves the right to change or modify any information or specifications without notice The contents of this User Manual are provided as is Except as required by applicable law no warranties of any kind either express or implied including but not limited to the implied warranties of merchanta...

Reviews: