User Manual
Page 3 / 6
HLK-LD015-5G
5. Electrical parameters
6. Sensing time and sensing distance adjustment
HLK-LD015-5G requires 3 pins by default, namely VCC, GND and OUT. At this time, the
induction delay and induction distance are fixed values. If you need to adjust the induction delay
and induction distance and other related parameters, you need to add 2 pins, RX and TX, on the
hardware as shown in Figure 3. In software configuration, RX and TX can be used as I/O ports or
UART ports to adjust module parameters. These two PINs are regarded as I/O ports by default,
where TX is used to adjust the sensing distance, its sensing distance is 4~6 meters at low level
while 3~5 meters at high level; RX is used to adjust the delay time, its sensing delay time is 30S at
low level while 2s at high level. When the sensing is triggered again within the delay time, the
timing will restart. RX and TX can also be used both as UART port to adjust the module parameters,
and serial ports.
Parameters
Minimum
Value
Typical
Value
Maximum
Value
Unit
Remarks
Transmit frequency
5725
5875
MHz
Transmit power
0.5
1
mW
Input voltage
4.5
5
5.5
V
LDO is not attached by
default
Output high level
5
V
Output low level
0
V
Working current
38
50
mA
Hanging height
3
5
M
Adjustable according
to specific needs
Sensing radius
4
6
M
Related to sensitivity
and hanging height
Delay time
30
S
Adjustable according
to specific needs
Photosensitive threshold
10
Lux
Adjustable according
to specific needs
Operating temperature
-30
85
°C