![Hi-Force TWE Series Operating Instructions Manual Download Page 15](http://html1.mh-extra.com/html/hi-force/twe-series/twe-series_operating-instructions-manual_2128879015.webp)
OPERATING INSTRUCTIONS:
Electric Torque Wrench
Series: TWE
TDS:-
1399
Prepared by:- M.DAVIES
Approved by:-
Date: 25/03/14
REV NO:-
1
ECO:-
Page
15
of
20
The two diode lights flash red alternately. The
error is documented.
Remedy: Unplug the tool and plug in again. If
the error is still present, send device to Hi-Force
Limited.
3.5.2
Error in the temperature sensor
If there is any error in temperature
measurement, the message Sys02 flashes in the
display for 3 seconds.
Bolting process is interrupted.
Additionally, an acoustic warning signal is
emitted.
The two diode lights flash red alternately. The
error is documented.
Remedy: Unplug the tool and plug in again. If
the error is still present, send device to Hi-Force
Limited.
3.5.3 Error motor overcurrent
If there is any error in motor over-current, the
message Sys03 flashes in the display for 3
seconds.
Bolting process is interrupted.
Additionally, an acoustic warning signal is
emitted.
The two diode lights flash red alternately. The
error is documented.
Remedy: Unplug the tool and plug in again. If
the error is still present, send device to Hi-Force
Limited.
Cause: Blockage of motor in clockwise rotation,
or short circuit in the coil.