![Hi-Force MHP100 Instruction Manual Download Page 1](http://html1.mh-extra.com/html/hi-force/mhp100/mhp100_instruction-manual_2128898001.webp)
INSTRUCTION MANUAL:
Model Series: MHP100 –MHP1000 inclusive
Hi-Force Limited – Prospect Way – Daventry – Northants NN11 8PL – United Kingdom
Tel: +44(0) 1327 301000: Fax: +44(0) 1327 706555: Website: www.hi-force.com
Hydrotest Pump Series: MHP100 – MHP1000
1.0
Inspection of the product upon receipt:
On receipt of the product, visually inspect the
item for any evidence of shipping damage.
Please note shipping damage is not covered
by warranty. If shipping damage is found notify
the carrier immediately and refrain from putting
the product into service. The carrier is
responsible for repair and replacement costs
resulting from damage in transit shipment.
2.0
Safety Precautions:
Read and follow all the instructions and safety
warnings carefully prior to use of the equipment.
Failure to do so could result in equipment
damage or failure of the equipment or personal
injury. Hi-Force will not be held responsible for
any damage to the equipment or personal
injury resulting from unsafe use of the product,
lack of maintenance or incorrect operation. If in
doubt on the correct usage of any Hi-Force
equipment, contact your nearest Hi-Force office
or distributor. If the operator has not been
trained on high pressure hydraulic equipment
and its safe use consult your local Hi-Force sales
office who can offer you training courses for
operators.
All operators should ensure that all necessary
personal protective equipment as specified by
their employer is worn when operating any
hydraulic equipment. Safety shoes, safety
glasses/ visor and protective gloves should be
worn at all
times. All relevant risk assessments
should be completed prior to use of the
equipment.
MHP PUMP SELECTION CHART
Safety
Read this entire manual before operating the
pump.
Failure to observe the following warnings could
result in serious bodily injury.
Ensure that all equipment connected is
in good conditions and is rated for the
operating pressure of the pump
Whenever possible, use a pressure
gauge with the pump. The optional
gauge is easily fitted to the top of the
pump. See selection chart for correct
gauge
Only use hydraulic hoses in good
condition that have a safety factor on
burst pressure of 4:1.
Ensure reservoir has sufficient capacity
for the required operation.
Do not handle hoses that are
pressurised. Oil escaping under
pressure will penetrate the skin causing
serious injury.
Danger: If oil is injected under the skin consult a
doctor immediately.
Never pressurise uncoupled hose
couplers
Always wear appropriate Personal
Protective Equipment when using this
pump.
Pump
Model
Number
Maximum
Working
Pressure
(Bar)
Low Pressure
Displacement
Per Stroke
(cm3)
High Pressure
Displacement
Per Stroke
(cm3)
Optional
Pressure
Gauge Kit
MHP100
100
50
22
MHP100GK
MHP300
300
50
8
MHP300GK
MHP500
500
50
4
MHP500GK
MHP700
700
50
3
MHP700GK
MHP1000
1000
50
2
MHP1000GK