Hi-Force MHP100 Instruction Manual Download Page 1

 

INSTRUCTION MANUAL:  

Model Series:  MHP100 –MHP1000 inclusive 

Hi-Force Limited – Prospect Way – Daventry – Northants NN11 8PL – United Kingdom 
Tel: +44(0) 1327 301000:  Fax: +44(0) 1327 706555: Website: www.hi-force.com  

 

Hydrotest Pump Series: MHP100 – MHP1000 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 

 
 
 
 
 
 
 
 
 
1.0

 

Inspection of the product upon receipt: 

On receipt of the product, visually inspect the 
item for any evidence of shipping damage. 
Please note shipping damage is not covered 
by warranty. If shipping damage is found notify 
the carrier immediately and refrain from putting 
the product into service. The carrier is 
responsible for repair and replacement costs 
resulting from damage in transit shipment. 
2.0

 

Safety Precautions: 

 

Read  and  follow  all  the  instructions and  safety 
warnings carefully prior to use of the equipment. 
Failure  to  do  so  could  result  in  equipment 
damage or failure of the equipment or personal 
injury.  Hi-Force  will  not  be  held  responsible  for 
any  damage  to  the  equipment  or  personal 
injury resulting  from  unsafe  use  of  the  product, 
lack of maintenance or incorrect operation. If in 
doubt  on  the  correct  usage  of  any  Hi-Force 
equipment, contact your nearest Hi-Force office 
or  distributor.  If  the  operator  has  not  been 
trained  on  high  pressure  hydraulic  equipment 
and its safe use consult your local Hi-Force sales 

office  who  can  offer  you  training  courses  for 
operators. 

 

All operators should ensure that all necessary 
personal protective equipment as specified by 
their employer is worn when operating any 
hydraulic equipment. Safety shoes, safety 
glasses/ visor and protective gloves should be 
worn at all

 

times. All relevant risk assessments 

should be completed prior to use of the 
equipment. 

MHP PUMP SELECTION CHART 

 

 
 

 

Safety 

Read  this  entire  manual  before  operating  the 
pump. 
Failure to observe the following warnings could 
result in serious bodily injury. 

 

Ensure that all equipment connected is 
in good conditions and is rated for the 
operating pressure of the pump 

 

Whenever  possible,  use  a  pressure 
gauge  with  the  pump.  The  optional 
gauge is easily fitted to the top of the 
pump.  See  selection  chart  for  correct 
gauge 

 

Only  use  hydraulic  hoses  in  good 
condition that have a safety factor on 
burst pressure of 4:1. 

 

Ensure reservoir has sufficient capacity 
for the required operation. 

 

Do not handle hoses that are 
pressurised. Oil escaping under 
pressure will penetrate the skin causing 

                serious injury.  
Danger: If oil is injected under the skin consult a 
doctor immediately. 

 

Never  pressurise  uncoupled  hose 
couplers 

 

Always  wear  appropriate  Personal 
Protective  Equipment  when  using  this 

pump. 

Pump 
Model 
Number 

Maximum 
Working 
Pressure 
(Bar) 

Low Pressure 
Displacement 
Per Stroke 
(cm3) 

High Pressure 
Displacement 
Per Stroke 
(cm3) 

Optional 
Pressure 
Gauge Kit 

MHP100 

100 

50 

22 

MHP100GK 

MHP300 

300 

50 

MHP300GK 

MHP500 

500 

50 

MHP500GK 

MHP700 

700 

50 

MHP700GK 

MHP1000 

1000 

50 

MHP1000GK 

Reviews: