INSTRUCTION MANUAL – AIR DRIVEN HYDRAULIC PUMPS:  

Model Series: AHP1120, AHP1120R, AHP1121, AHP1121R, AHP1122, AHP1122R, AHP1141, AHP1142,  

HAP21011, HAP21012, HAP21014, HAP21016, HAP21021, HAP21022, HAP21024, HAP21026, HAP21031, 

HAP21032, HAP21034, HAP21036, HAP21041, HAP21042, HAP21044, HAP21046,   

Hi

Force

 

Limited

 

 

Prospect

 

Way

 

 

Daventry

 

 

Northants

 

NN11

 

8PL

 

 

United

 

Kingdom

 

Tel:

 

+44(0)

 

1327

 

301000:

  

Fax:

 

+44(0)

 

1327

 

706555:

 

Website:

 

www.hi

force.com

  

 

Always operate the system under no load 
condition prior to the actual lift to ensure that 
no air is trapped in the hydraulic circuit. 
Do not drop or place heavy objects on a 
hydraulic hose as this will cause internal 
damage to the hose which could result in 
rupture when the hose is pressurized and could 
result in serious damage to components, and 
possible serious personal injury to operating 
personnel. 

3.0

 

Description

 

AHP

 

series

 

Air

 

Driven

 

Pumps.

 

 

The device supplied is an air-powered 

hydraulic pump that converts a compressed air 
supply into a pressurized hydraulic flow (see 
“Technical specifications” – table below Fig 2).  
The pump can be utilized to power single and 
double acting hydraulic cylinders; in the latter 
case a directional control valve between 
pump and cylinder is required. The filler/ 
breather plug can be removed and used as a 
return line. (or select model AHP 1141/ 1142).  
Any other uses of the pump shall be considered 
improper and can cause serious accidents. The 
manufacturer declines all liability for damages 

resulting from improper use of the pump.  
 
The main components of the pump 
 

 
Note: Models ending with “R” (AHP1120R/ 
1121R/ 1122R) are operated with a hand 

pendant instead of a treadle (Fig 16). 

 

4.0 Safety: 

Observe all the following safety rules. They are 
of the maximum importance for your own 
safety and the safety of others. In addition to 
the safety warnings in this section, please also 
take note of all safety related issues in other 
sections of this manual.  

 

DO NOT TAMPER WITH THE PROTECTIONS 
AND SAFETY DEVICES AND DO NOT 
MODIFY THE PUMP IN ANY WAY TO 

AVOID CREATING

 

POTENTIALLY 

HAZARDOUS SITUATIONS FOR WHICH 
THE

 

OPERATOR OR THE SERVICE 

TECHNICIAN IS UNPREPARED.  

 

REMOVING OR TAMPERING WITH ANY 
OF THE SAFETY DEVICES ON THE PUMP 

AUTOMATICALLY INVALIDATES THE 
WARRANTY AND ABSOLVES THE 
MANUFACTURER FROM ALL LIABILITY
 

 

5.0 Installation and start up: 
If these instructions are disregarded, the person 
who is responsible for the modifications 
automatically assumes full liability for any 
accidents that may occur during use of the 
pump.  
Pump model AHP 
1120/1120R/1121/1121R/1122/1122R/1141/1142 
can be installed in a horizontal or vertical 
position.  
5.1. Filling the reservoir (if the pump is supplied 
without oil) 
 

The table above (Fig 2.) shows the oil quantities 
required to fill the pump reservoir. The table 
also shows the actual usable oil capacities.  
Use only HI-FORCE HFO46 oil for your AHP 
Pump.  
The manufacturer shall not be held responsible 
for injury to people or damage to property 
caused by the use of incorrect hydraulic oil. 
Damage to the pump resulting from the above 
mentioned causes is not covered by warranty. 

 

Use a slotted tip screwdriver to remove 
the filler plug (Fig:1) 

 

Pour the correct quantity of oil into the 
reservoir (see table at Fig:2) 

 

Clean the edges of the filler opening 
with a clean cloth and refit the plug, 
pressing it down fully. 

5.2.1 - Pump hydraulic connections Models 
AHP1120/ AHP1121/ AHP1122
 

 

Connect the hydraulic pressure hose to 
(Port A Fig:14). The hose must be fitted 
with a 3/8” NPTF fitting after binding the 
thread with Teflon tape. 

 

Unscrew the breather screw (Fig: 6) by 
three or four turns using an appropriate 
screwdriver. 

Summary of Contents for AHP1120б Series

Page 1: ...nt as specified by their employer is worn when operating any hydraulic equipment Safety shoes safety glasses visor and protective gloves should be worn at all times All relevant risk assessments shoul...

Page 2: ...ximum importance for your own safety and the safety of others In addition to the safety warnings in this section please also take note of all safety related issues in other sections of this manual DO...

Page 3: ...essed air line Select a quick coupler that is compatible with the air line supply and connect it to the air inlet connection Fig 1 6 Operation 6 1 AHP1120 AHP1121 AHP1122 To start the pump press down...

Page 4: ...n is released the pump stops but the pressure is maintained on the oil side so that the connected cylinder holds the load in the position it has reached To return the pressure to zero and hence retrac...

Page 5: ...ing the recommended types of oil 7 3 2 Checking the hydraulic oil on the 5 10 Litre pump AHP1121 R 1122 R 1141 1142 Periodically check the oil level which must be between the two notches on the oil ca...

Page 6: ...t hoses regularly for damage and wear Do not use hoses that are frayed abraded or leaking Never move the pump by pulling the hoses Do not work with hoses sharply bent or kinked Do not handle hoses tha...

Page 7: ...the shipping company 2 Establish the oil level in the oil reservoir using the level gauge on the end of the tank Depending on the shipping method used the reservoir may either be supplied full or empt...

Page 8: ...t anti clockwise will supply oil to the port and advance the cylinder Moving the lever away from the service port will connect the service port to tank and retract the cylinder 4 For pumps with 4 way...

Reviews: