Summary of Contents for IMAGETEAM 5600

Page 1: ...IMAGETEAM 5600 Light Commercial Hand Held Linear Imager User s Guide...

Page 2: ...ment on the part of HHP HHP shall not be liable for technical or editorial errors or omissions contained herein nor for incidental or consequential damages resulting from the furnishing performance or...

Page 3: ...and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and r...

Page 4: ...with equipment i e power supplies personal computers etc that is not CE marked and does not comply with the Low Voltage Directive UL and cUL Statement UL listed UL1950 and CSA 22 2 No 950 cUL listed...

Page 5: ...9 1 7 IBM 4683 Ports 5B 9B and 17 Interface 1 8 Connecting the Scanner with USB 1 9 Connecting the Scanner with Serial Wedge 1 10 Chapter 2 Terminal Interfaces Keyboard Wedge Connection 2 1 Terminal I...

Page 6: ...ial Trigger 3 3 Automatic Trigger 3 5 Presentation Mode 3 5 Centering 3 5 Chapter 4 Data Editing Prefix Suffix Overview 4 1 To Clear One or All Prefixes or Suffixes 4 3 To Add a Carriage Return Suffix...

Page 7: ...Decoded Output Laser Emulation Transmission Rate 6 2 Non Decoded Output Laser Emulation Polarity 6 2 Non Decoded Laser Emulation Idle 6 3 Disabling the Secondary Interface 6 3 Secondary Trigger Mode...

Page 8: ...h 7 14 Code 128 7 14 ISBT 128 Concatenation 7 15 Code 128 Message Length 7 15 Telepen 7 16 Telepen Output 7 16 Telepen Message Length 7 16 UPC A 7 17 UPC A Check Digit 7 17 UPC A Number System 7 17 UP...

Page 9: ...ck Character 7 26 MSI Message Length 7 26 Plessey Code 7 27 Plessey Message Length 7 27 RSS Limited 7 28 RSS Expanded 7 29 RSS Expanded Message Length 7 29 China Post Code 7 29 Korea Post Code 7 30 Ko...

Page 10: ...of Multiple Commands 10 2 Responses 10 2 Examples of Query Commands 10 3 Trigger Commands 10 4 Resetting the Standard Product Defaults 10 4 Menu Commands 10 5 Chapter 11 Product Specifications IMAGETE...

Page 11: ...vii Help Desk 13 2 Limited Warranty 13 4 Appendix A Symbology Chart A 1 ASCII Conversion Chart Code Page 1252 A 2 Sample Symbols...

Page 12: ...viii...

Page 13: ...lications About This Manual This User s Guide provides installation and programming instructions for the IMAGETEAM 5600 Product specifications dimensions warranty and customer support information are...

Page 14: ...es Models Primary Secondary 5600SR000 TTL Level 232 Lower Power HHLC 5600SR010 Keyboard Wedge TTL level 232 TTL level 232 serial wedge IBM 4683 wand emula tion Wand Emulation TTL level 232 5600SR030 T...

Page 15: ...1 3 IT5600 Scanner Identification...

Page 16: ...de The following is an example of a keyboard wedge connection 1 Turn off power to the terminal computer 2 Disconnect the keyboard cable from the back of the terminal computer 3 Connect the appropriate...

Page 17: ...an appropriate distance from the target pull the trigger and center the aiming line on the symbol Resetting the Standard Product Defaults If you aren t sure what programming options are in your scann...

Page 18: ...laptops scanning the Laptop Direct Connect bar code allows operation of the integral keyboard The following Laptop Direct Connect bar code also programs a carriage return CR suffix RS 232 The RS 232 I...

Page 19: ...converts all other symbologies to Code 39 It also programs the Transmission Rate to 25 inches per second and Output Polarity to black high Wand Emulation Code 39 Note This interface applies to the 56...

Page 20: ...ove also programs the following suffixes for each symbology Suffixes programmed for Code 128 with IBM 4683 Port 5B IBM 4683 Port 9B HHBCR 1 and IBM 4683 Port 17 Interfaces Suffixes programmed for Code...

Page 21: ...e back cover of this manual Note The following USB Plug and Play codes are supported on specific IT5600 models Refer to IT5600 Models on page 1 2 to determine if this interface applies to your scanner...

Page 22: ...code to program the IT5600 for USB HID bar code scanners Scanning this code changes the terminal ID to 131 Connecting the Scanner with Serial Wedge The IT5600 uses True and TTL signal levels to wedge...

Page 23: ...power pack cable into the receptor on the scanner cable 7 Plug the power pack into a power source 8 Once the scanner has been fully connected power up the computer To set up the serial wedge terminal...

Page 24: ...1 12...

Page 25: ...page 2 2 through page 2 3 and locate the Terminal ID number for your PC Scan the Terminal ID bar code below then scan the numeric bar code s from the Programming Chart inside the back cover of this m...

Page 26: ...477 3486 3482 3488 008 IBM 122 key 3180 024 IBM 122 key 3180 data entry keyboard 114 IBM DOS V 106 key PC Workstation 102 IBM SurePOS USB Hand Held Scanner 128 IBM SurePOS USB Tabletop Scanner 129 IBM...

Page 27: ...following characters are supported but need special care for countries other than the United States Note Please refer to HHP s website www HHP com for complete keyboard country support information and...

Page 28: ...the Caps Lock status Emulate External Keyboard should be scanned if you do not have an external keyboard IBM AT or equivalent To connect the scanner to a laptop it may be necessary to use the Automat...

Page 29: ...aracters to a terminal faster If the terminal drops characters do not use Turbo Mode Default Off Numeric Keypad Mode Sends numeric characters as if entered from a numeric keypad Default Off Automatic...

Page 30: ...e power tap on the scanner cable 4 Plug the power tap into the mouse or keyboard port 5 Plug the serial connector into the serial port on your computer Tighten the two screws to secure the connector t...

Page 31: ...e Baud Rate sends the data from the scanner to the terminal at the specified rate The host terminal must be set for the same baud rate as the scanner Default 38 400 300 2400 600 1200 4800 38400 9600 1...

Page 32: ...tions which require use of the full ASCII set select 8 data bits per character Default 8 Stop Bits sets the stop bits at 1 or 2 Default 1 Parity provides a means of checking character bit patterns for...

Page 33: ...ds data in the same format as a wand scanner The Code 39 Format converts all symbologies to Code 39 The Same Code Format transmits UPC EAN Code 128 and Interleaved 2 of 5 without any changes but conve...

Page 34: ...the terminal s ability to receive data without dropping characters Default 25 inches second Wand Emulation Polarity The Polarity can be sent as standard with black bars high or reversed with white ba...

Page 35: ...ibes the state of the scanner when no data is being transmitted When in Wand Emulation mode you must set the scanner s idle state to match the idle state for the device to which the scanner is connect...

Page 36: ...2 12...

Page 37: ...d indication All error and menu beeps are still audible Default On Beeper Volume Good Read The beeper volume codes modify the volume of the beep the scanner emits on a good read Default Low Beeper Pit...

Page 38: ...and five LED flashes in response to a good read The beeps and LED flashes are in sync with one another To change the number of beeps scan the bar code below and then scan a digit 1 9 bar code and the...

Page 39: ...code Default No Delay Trigger Modes Manual Serial Trigger You can activate the scanner either by pressing the trigger or using a serial trigger command see Trigger Commands on page 10 4 When in manua...

Page 40: ...anual Trigger Low Power The scanner powers down until the trigger is pulled When the trigger is pulled the scanner powers up and operates until there is no triggering for the time set with the Low Pow...

Page 41: ...arrow the imager s field of view to make sure that the imager reads only the bar code you want For instance if multiple codes are placed closely together centering will make certain that only the desi...

Page 42: ...AVE from the Programming Chart inside the back cover of this manual The figure below illustrates the percentage range from 1 to 100 Example If you have two bar codes next to one another and the center...

Page 43: ...following illustration shows the breakdown of a message string Points to Keep In Mind It is not necessary to build a message string The selections in this chapter are only used if you wish to alter t...

Page 44: ...ep 7 To add the Code I D scan 5 C 8 0 To add AIM I D scan 5 C 8 1 To add a backslash scan 5 C 5 C Note To add a backslash as in Step 7 you must scan 5C twice once to create the leading backslash and t...

Page 45: ...termine the 2 digit Hex value from the Symbology Chart included in the Appendix A for the symbology from which you want to clear the pre fix or suffix Step 3 Scan the 2 digit hex value from the Progra...

Page 46: ...the scan code is converted to a key code before it is transmitted Default Enable Intercharacter Interfunction and Intermessage Delays Some terminals drop information characters if data comes through t...

Page 47: ...cter delay of up to 495 milliseconds may be placed after the transmission of a particular character of scanned data Scan the Delay Length bar code below then scan the number of milliseconds and the SA...

Page 48: ...ide the back cover of this manual Intermessage Delay An intermessage delay of up to 495 milliseconds may be placed between each scan transmission Scan the Intermessage Delay bar code below then scan t...

Page 49: ...versal Term ID Actual Code ID Universal Length 7 Universal Term ID Universal Code ID Actual Length 8 Universal Term ID Universal Code ID Universal Length If you have changed data format settings and w...

Page 50: ...an alternate format scan 1 2 or 3 depending on the alternate format you are clearing Scan the Terminal Type refer to the Supported Terminals Chart on page 2 2 Code I D refer to the Symbology Chart on...

Page 51: ...Code Page 1252 on page A 2 F9 Search back for xx character from current cursor position leaving cursor pointing to xx character Syntax F9xx xx stands for the hex value for an ASCII code see ASCII Conv...

Page 52: ...l increment cursor If characters are not equal no format match Syntax FExx xx stands for the hex value for an ASCII code see ASCII Conversion Chart Code Page 1252 on page A 2 EC Check to make sure the...

Page 53: ...to scan one bar code using a different data format than your primary format When data formats are programmed see page 5 1 you must input whether you are programming the primary format or an alternate...

Page 54: ...5 6...

Page 55: ...hanges but converts all other symbologies to Code 39 These codes set the transmission rate to 25 inches per second and the output polarity to black high Default Code 39 Format Secondary RS 232 Connect...

Page 56: ...ion Use this selection when connecting to a secondary terminal with integral decoding This also sets the transmission rate to 36 scans per second and the polarity to white high Non Decoded Output Lase...

Page 57: ...temporarily disable the secondary interface but still retain the secondary interface settings in the scanner s memory by scanning the Disable bar code below To re enable the secondary interface scan t...

Page 58: ...sleeps until the trigger is pulled When the trigger is pulled the scanner wakes up and operates at normal power until there is no triggering for the time set with the Low Power Time Out bar code Then...

Page 59: ...particular symbology scan All Symbologies Off followed by the On symbol for that particular symbology Note If you are going to scan Code 32 Pharmaceutical you must turn Trioptic Code off All Symbologi...

Page 60: ...nces of a misread EXAMPLE Decode only those bar codes with a count of 9 20 characters Min length 09 Max length 20 EXAMPLE Decode only those bar codes with a count of 15 characters Min length 15 Max le...

Page 61: ...re created using different modulos You can program the scanner to read only Codabar bar codes with Modulo 16 check characters Default No Check Character No Check Character indicates that the scanner r...

Page 62: ...abar symbol having a D start character adjacent to a symbol having a D stop character In this case the two messages are concatenated into one with the D characters omitted Default On Select Require to...

Page 63: ...lengths 2 60 Minimum Default 4 Maximum Default 60 Code 39 Default All Code 39 Settings Code 39 Code 39 Start Stop Characters Start Stop characters identify the leading and trailing ends of the bar cod...

Page 64: ...data When Check Character is set to Validate and Transmit the scanner only reads Code 39 bar codes printed with a check character and will transmit this character at the end of the scanned data Defau...

Page 65: ...not immediately transmit the data The scanner stores the data in the order in which the bar codes are read deleting the first space from each The scanner transmits the appended data when it reads a C...

Page 66: ...h Y decode as 0 through 9 NUL U DLE P SP SPACE 0 0 V P P W p P SOH A DC1 Q A 1 1 A A Q Q a A q Q STX B DC2 R B 2 2 B B R R b B r R ETX C DC3 S C 3 3 C C S S c C s S EOT D DC4 T D 4 4 D D T T d D t T E...

Page 67: ...ut Don t Transmit the unit only reads Interleaved 2 of 5 bar codes printed with a check digit but will not transmit the check digit with the scanned data When Check Digit is set to Validate and Transm...

Page 68: ...inimum Default 4 Maximum Default 80 Code 93 Default All Code 93 Settings Code 93 Code 93 Message Length Scan the bar codes below to change the message length Refer to Message Length on page 7 2 for ad...

Page 69: ...n the bar codes below to change the message length Refer to Message Length on page 7 2 for additional information Minimum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 IATA Code 2 of 5...

Page 70: ...w to change the message length Refer to Message Length on page 7 2 for additional information Minimum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 Matrix 2 of 5 Default All Matrix 2 o...

Page 71: ...nformation Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 Code 11 Default All Code 11 Settings Code 11 Check Digits Required This option sets whether 1 or 2 check digits are req...

Page 72: ...low to change the message length Refer to Message Length on page 7 2 for additional information Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 Code 128 Default All Code 128 Sett...

Page 73: ...de 128 due to its high degree of security and its space efficient design 3 a variation of Code 128 that supports concatenation of neighboring symbols and 4 the standard layout for bar codes on a blood...

Page 74: ...ols with start stop pattern 1 and decodes them as compressed numeric with optional full ASCII start stop pattern 2 Default AIM Telepen Output Telepen Message Length Scan the bar codes below to change...

Page 75: ...er the check digit should be transmitted at the end of the scanned data or not Default On UPC A Number System The numeric system digit of a U P C symbol is normally transmitted at the beginning of the...

Page 76: ...da Required is set to on the scanner will only read UPC A bar codes that have addenda Default Not Required UPC A Addenda Separator When this feature is on there is a space between the data from the ba...

Page 77: ...Code Default On UPC E Default All UPC E Settings UPC E0 and UPC E1 Most U P C bar codes lead with the 0 number system For these codes use the UPC E0 selection If you need to read codes that lead with...

Page 78: ...Required When Addenda Required is set to on the scanner will only read UPC E bar codes that have addenda Default Not Required UPC E0 and UPC E1 Addenda Separator When this feature is on there is a spa...

Page 79: ...system digit of a U P C symbol is normally transmitted at the beginning of the scanned data but the unit can be programmed so it will not transmit it Default On UPC E0 Addenda This selection adds 2 o...

Page 80: ...the check digit should be transmitted at the end of the scanned data or not Default On EAN JAN 13 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN JAN 13 data Default Off for b...

Page 81: ...n there is a space between the data from the bar code and the data from the addenda When turned off there is no space Default On Note If you want to enable or disable EAN13 with Extended Coupon Code r...

Page 82: ...the check digit should be transmitted at the end of the scanned data or not Default On EAN JAN 8 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN JAN 8 data Default Off for bot...

Page 83: ...ead EAN JAN 8 bar codes that have addenda Default Not Required EAN JAN 8 Addenda Separator When this feature is on there is a space between the data from the bar code and the data from the addenda Whe...

Page 84: ...ansmit this character at the end of the scanned data When Check Character is set to Validate but Don t Transmit the unit will only read MSI bar codes printed with the specified type check character bu...

Page 85: ...Length Scan the bar codes below to change the message length Refer to Message Length on page 7 2 for additional information Minimum and Maximum lengths 4 48 Minimum Default 4 Maximum Default 48 RSS 14...

Page 86: ...7 28 RSS 14 continued RSS 14 RSS Limited Default All RSS Limited Settings RSS Limited RSS Expanded Default All RSS Expanded Settings On Off On Off...

Page 87: ...w to change the message length Refer to Message Length on page 7 2 for additional information Minimum and Maximum lengths 4 74 Minimum Default 4 Maximum Default 74 China Post Code Default All China Po...

Page 88: ...o change the message length Refer to Message Length on page 7 2 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 80 Korea Post Code Default All Korea Post...

Page 89: ...ow to change the message length Refer to Message Length on page 7 2 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 48 PosiCode Default All PosiCode Setti...

Page 90: ...age length Refer to Message Length on page 7 2 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 48 Trioptic Code Trioptic Code is used for labeling magneti...

Page 91: ...th Scan the bar codes below to change the message length Refer to Message Length on page 7 2 for additional information Minimum and Maximum lengths 1 2048 Minimum Default 1 Maximum Default 2048 Code 1...

Page 92: ...change the message length Refer to Message Length on page 7 2 for additional information Minimum and Maximum lengths 0 160 Minimum Default 1 Maximum Default 160 Code 49 Default All Code 49 Settings Co...

Page 93: ...an the bar codes below to change the message length Refer to Message Length on page 7 2 for additional information Minimum and Maximum lengths 1 81 Minimum Default 1 Maximum Default 81 Minimum Message...

Page 94: ...7 36...

Page 95: ...ed with the scanner Refer to page 2 5 enable Control ASCII mode Function Code HEX ASCII Value Full ASCII CTRL NUL 00 2 SOH 01 A STX 02 B ETX 03 C EOT 04 D ENQ 05 E ACK 06 F BEL 07 G BS 08 H HT 09 I LF...

Page 96: ...ply to US only The following chart indicates the equivalents of these five characters for different countries Country Codes United States 6 Belgium 6 Scandinavia 8 9 6 France 8 6 Germany 6 Italy 6 Swi...

Page 97: ...e BS 08 Reserved Reserved F16 HT 09 Tab Tab F17 LF 0A Reserved Reserved F18 VT 0B Tab Tab Tab Field Forward FF 0C Delete Delete Delete CR 0D CR Enter CR Enter Field Exit New Line SO 0E Insert Insert I...

Page 98: ...ed VT 0B Tab Field Forward Field Forward FF 0C Delete Delete CR 0D Field Exit New Line SO 0E Insert Insert SI 0F Clear Erase DLE 10 Error Reset Error Reset DC1 11 Home Reserved DC2 12 Print Print DC3...

Page 99: ...w Line New Line New Line BS 08 N A N A N A HT 09 Tab Tab Tab LF 0A N A N A N A VT 0B Tab Tab Tab FF 0C N A N A Delete CR 0D New Line New Line New Line SO 0E N A N A Insert SI 0F Escape Escape Escape D...

Page 100: ...k ENQ 05 CNTRL make ACK 06 CNTRL break BEL 07 RETURN BS 08 APPLE make HT 09 TAB LF 0A APPLE break VT 0B TAB FF 0C Del CR 0D RETURN SO 0E Ins Help SI 0F ESC DLE 10 F11 DC1 11 Home DC2 12 Prnt Scrn DC3...

Page 101: ...elow to output the current software revision unit serial number and other product information Show Data Format Scan the bar code below to show current data format settings Resetting the Standard Produ...

Page 102: ...scan the bar code below and the unit will communicate in RS 232 mode allowing it to work with Visual Menu To convert the scanner back to keyboard wedge communication cycle the power Note If you downlo...

Page 103: ...creen Menu Command Syntax Menu commands have the following syntax spaces have been used for clarity only Prefix Tag SubTag Data SubTag Data Tag SubTag Data Storage Prefix Three ASCII characters SYN M...

Page 104: ...ecause it is ignored by the device Data Field Usage When a query is used in place of the Data field the query applies only to the specific command identified by the Tag and SubTag fields Concatenation...

Page 105: ...s response indicates that the default setting for Codabar Coding Enable CBRENA is 1 or on Example 3 What is the device s current setting for Codabar Coding Enable Enter cbrena Response CBRENA1 ACK Thi...

Page 106: ...scanner scans until a bar code has been read until the deactivate com mand is sent or until the serial time out has been reached see Serial Trigger Time Out on page 3 4 for a description and the seri...

Page 107: ...matic Caps Lock KBDSTY6 2 4 Emulate External Keyboard KBDSTY5 2 4 Keyboard Modifiers Control ASCII Off KBDCAS0 2 5 Control ASCII On KBDCAS1 2 5 Turbo Mode Off KBDTMD0 2 5 Turbo Mode On KBDTMD1 2 5 Num...

Page 108: ...CTS On 232CTS1 2 9 XON XOFF Off 232XON0 2 9 XON XOFF On 232XON1 2 9 ACK NAK Off 232ACK0 2 9 ACK NAK On 232ACK1 2 9 Wand Emulation Connec tion Same Code Format WNDPAT0 2 9 Code 39 Format WNDPAT1 2 9 W...

Page 109: ...RDDLY0 3 3 Medium RRDDLY1 3 3 Long RRDDLY2 3 3 Extra Long RRDDLY3 3 3 Good Read Delay No Delay GRDDLY0 3 3 Short Delay GRDDLY1 3 3 Medium Delay GRDDLY2 3 3 Long Delay GRDDLY3 3 3 Trigger Mode Manual S...

Page 110: ...ta Format None DFMDF3 5 4 Enter Data Format DFMBK3 5 4 Clear One Data Format DFMCL3 5 4 Clear All Data Formats DFMCA3 5 4 Data Formatter Off DFM_EN0 5 5 On but Not Required DFM_EN1 5 5 On Required DFM...

Page 111: ...ogies On ALLENA1 7 1 Codabar Default All Codabar Settings CBRDFT 7 3 Codabar Off CBRENA0 7 3 On CBRENA1 7 3 Codabar Start Stop Char Don t Transmit CBRSSX0 7 3 Transmit CBRSSX1 7 3 Codabar Check Char N...

Page 112: ...I25ENA1 7 9 Interleaved 2 of 5 Check Digit No Check Char I25CK20 7 9 Validate But Don t Transmit I25CK21 7 9 Validate and Transmit I25CK22 7 9 Interleaved 2 of 5 Message Length Minimum 2 80 4 I25MIN 7...

Page 113: ...NA0 7 13 On C11ENA1 7 13 Code 11 Check Digits Required 1 Check Digit C11CK20 7 13 2 Check Digits C11CK21 7 13 Code 11 Message Length Minimum 1 80 4 C11MIN 7 14 Maximum 1 80 80 C11MAX 7 14 Code 128 Def...

Page 114: ...Addenda Required Not Required UPAARQ0 7 18 Required UPAARQ1 7 18 UPC A Addenda Separator Off UPAADS0 7 18 On UPAADS1 7 18 UPC E Default All UPC E Settings UPEDFT 7 19 UPC E0 Off UPEEN00 7 19 On UPEEN0...

Page 115: ...Required E13ARQ0 7 23 Required E13ARQ1 7 23 EAN JAN 13 Addenda Separator Off E13ADS0 7 23 On E13ADS1 7 23 ISBN Translate Off E13ISB0 7 23 On E13ISB1 7 23 EAN JAN 8 Default All EAN JAN 8 Settings EA8DF...

Page 116: ...gth Minimum 4 48 4 PLSMIN 7 27 Maximum 4 48 48 PLSMAX 7 27 RSS 14 Default All RSS 14 Settings RSSDFT 7 28 RSS 14 Off RSSENA0 7 28 On RSSENA1 7 28 RSS Limited Default All RSS 14 Limited Settings RSLDFT...

Page 117: ...Length Minimum 2 80 4 POSMIN 7 32 Maximum 2 80 48 POSMAX 7 32 Trioptic Code Off TRIENA0 7 32 On TRIENA1 7 32 Codablock F Default All Codablock F Set tings CBFDFT 7 33 Codablock F Off CBFENA0 7 33 On C...

Page 118: ...10 16...

Page 119: ...w Power 5600SR000 Model 5Vdc 235mA 68mA 350mA 100 A 5600SR000 Model 12Vdc 142mA 48mA N A N A 5600SR010 050 Model 5Vdc 235mA 68mA 350mA 100 A 5600SR010 050 Model 12Vdc 127mA 48mA N A N A 5600SR030 Mode...

Page 120: ...nt lighting 13 mil 100 UPC 1 in 2 5 cm 24 in 61 cm 7 5 mil Code 39 4 in 10 cm 14 in 36 cm 10 mil Code 39 2 in 5 cm 18 in 46 cm 13 mil Code 39 1 in 2 5 cm 24 in 61 cm 15 mil Code 39 1 in 2 5 cm 28 in 7...

Page 121: ...urn on good read LED or beeper N C Trigger signal to decoder 9 Pin Type D Female connects to your terminal Laser enable Supply ground Cord shield 5 Volt power connection 1 2 3 4 5 6 7 8 9 Pins 4 and 9...

Page 122: ...nects to the scanner handle 1 2 Cord shield 3 Prog 1 4 Supply ground 5 Terminal clock 6 Terminal data 7 Power connection Refer to table on page 11 1 8 Keyboard data 9 Keyboard clock 10 Decoded output...

Page 123: ...ed to 5 Volt power 4 Supply ground 5 6 Bar code data output 7 5 Volt power connection 8 9 10 Decoded output data format provided at 10 pin RJ41 modular connector in scanner handle Bar code data output...

Page 124: ...scanner handle 1 2 Cord shield 3 Tied to 5 Volt power 4 Supply ground 5 Receive data Serial data to scanner 6 Transmit data Serial data from scanner 7 5 Volt power connection 8 Request to send data 9...

Page 125: ...11 7 Standard Cable Pinouts USB 10 Pin Modular Plug connects to the scanner handle 1 2 Data 3 Tied to 5 volt power 4 Supply ground 5 6 7 5 volt power connection 8 9 10 Data...

Page 126: ...11 8...

Page 127: ...t cloth or facial tissue dampened with water or a mild detergent water solution If a detergent solution is used rinse with a clean tissue dampened with water only The scanner s housing may also be cle...

Page 128: ...release 4 Straighten one end of a paper clip 5 Insert the end of the paper clip into the small hole and press in This depresses the retention tab releasing the connector Pull the connector out while...

Page 129: ...code but the data is not displayed correctly on the host screen The scanner may not be programmed for the appropriate terminal interface For example you scan 12345 and the host displays es Reprogram...

Page 130: ...12 4...

Page 131: ...returning the product HHP Service Department 7510 E Independence Blvd Suite 200 Charlotte NC 28227 Telephone 800 782 4263 Fax 704 566 9904 For service in Europe please contact your HHP representative...

Page 132: ...Latin America please contact your HHP representative at the address that follows or your local distributor Latin America Office Hand Held Products Inc 5117 Castello Drive Suite 1 Naples FL 34103 Tele...

Page 133: ...13 3 Asia Telephone 852 2511 3050 E mail asia_support hhp com Latin America Telephone 239 263 7600 E mail la_support hhp com...

Page 134: ...satisfaction that the product is defective due to defects in materials or workmanship HHP at its sole option will either repair or replace the product without charge except for return shipping to HHP...

Page 135: ...y Code ID AIM ID Hex ID China Post Q X0 51 IATA 2 of 5 f Rm 66 Codabar a Fm 61 Interleaved 2 of 5 e lm 65 Codablock F q Om 71 Korea Post X0 3F Code 2 of 5 f Rm 66 Matrix 2 of 5 m X0 6D Code 11 h Hm 68...

Page 136: ...07 6B k 12 0C FF 44 2C 76 4C L 108 6C l 13 0D CR 45 2D 77 4D M 109 6D m 14 0E SO 46 2E 78 4E N 110 6E n 15 0F SI 47 2F 79 4F O 111 6F o 16 10 DLE 48 30 0 80 50 P 112 70 p 17 11 DC1 49 31 1 81 51 Q 113...

Page 137: ...B 203 CB 235 EB 140 8C 172 AC 204 CC 236 EC 141 8D 173 AD 205 CD 237 ED 142 8E 174 AE 206 CE 238 EE 143 8F 175 AF 207 CF 239 EF 144 90 176 B0 208 D0 240 F0 145 91 177 B1 209 D1 241 F1 146 92 178 B2 21...

Page 138: ...A 4...

Page 139: ......

Page 140: ...Sample Symbols UPC A 0 123456 7890 Interleaved 2 of 5 Code 128 EAN 13 1234567890 Code 128 9 780330 290951 654 EAN 8 3210 5 456123 8 0 UPC E...

Page 141: ...Sample Symbols Code 93 123456 9 Code 2 of 5 123456 Matrix 2 of 5 6543210 RSS 14 01 00123456789012 Code 39 Codabar BC321 A13579B...

Page 142: ......

Page 143: ...amming Chart A C Save B Discard F E D Note If you make an error while scanning the letters or digits before scanning Save scan Discard scan the correct letters or digits and Save again 0 2 6 1 7 5 4 3...

Page 144: ...5600 UG Rev B...