background image

 

 

 

3.Setting up the machine 

3.1 Filling the main tank for the first time 

Please follow these simple steps: 

1. Use a plastic container to prepare the electrolyte solution first outside the machine. 

Be sure to wear goggles 

and rubber gloves for security reasons;

 

2. The electrolyte concentration to use is around 15 grs/liter of water. Add the full package (500 grs) provided 
with the machine to 30 liters of water. You can use any type of water but try to avoid water with bad quality 
or too many salts (iron or calcium). Tap water will work fine; 

3. Insert the electric plug in the 230 V AC socket and turn the machine ON. The lateral fan and a red light, 
buzzing and blinking, (Minimum Level) will be turned ON; 

4. Open the water tank lid and pure gently the mixture inside the water tank avoiding any spell. As the water 
level raises in the tank the red buzzing light will be turned OFF; 

5. Continue adding the electrolyte solution until the green steady light is turned ON. When this light appears 
please stop adding electrolyte solution; 

6. Close the water tank lid making sure it is well tight. 

3.2 Refilling the main tank 

As you use the machine the water level inside the tank will start to descend. First the green will turn OFF. After 
around 100 hours of work the red light will start to buzz and blink. It´s time to refill the machine again with 
electrolyte solution 

For refilling please follow these simple steps: 

1. Use a plastic container to prepare the electrolyte solution first outside the machine. 

Be sure to wear goggles 

and rubber gloves for security reasons;

 

2. The electrolyte concentration to use is around 15 grs/liter of water. Add around 300 grs of Potassium 
Hidroxide 90% pure to 20 liters of good quality water. 

4. Open the water tank lid and pour gently the mixture inside the water tank avoiding any spell. As the water 
level raises in the tank the red buzzing light will be turned OFF once again; 

5. Continue adding the electrolyte solution until the green steady light is turned ON. When this light appears 
please stop adding electrolyte solution; 

6. Close the water tank lid making sure it is well tight. 

3.3Security Bubbler 

Summary of Contents for HYDROGEN TECH ECC230 AC

Page 1: ...ECC230 AC User Manual...

Page 2: ...2 Refilling the main tank 5 3 3 Security Bubbler 5 4 Working with the machine 7 4 1 General use 7 4 3 Cleaning the air filter box 7 4 3 Working amperage 7 5 Diesel Cars and DPF Filter Cleaning 9 5 Mai...

Page 3: ...ear or in front of the end of the hose the protection bubbler inside the machine could blow up Be sure to wear goggles and rubber gloves and only use professional tools use common sense and general sa...

Page 4: ...nents of the machine Ammeter Water level lights Security Bubbler Water Tank Lid Ventilation Power Controls Emergency Switch Wheels Bubbler Cap Hydrogen Hose Power Cable AC Version Electric Plug Fronta...

Page 5: ...this light appears please stop adding electrolyte solution 6 Close the water tank lid making sure it is well tight 3 2 Refilling the main tank As you use the machine the water level inside the tank w...

Page 6: ...ory The level of this solution should be kept between the 2 marks in the metallic protection If the level drops below the inferior mark then you should refill the bubbler For refilling the bubbler ple...

Page 7: ...st 20 minutes of treatment increase the rotations of your engine to 1000 rpm and press second red power control button Check again amperage in the ammeter 9 Keep the machine working for one 1 hour to...

Page 8: ...the amperage is higher than 40A please add more water to dilute the solution and reduce the amperage b If the amperage is lower than 30A please add a little bit more electrolyte in order to raise the...

Page 9: ...right conditions the filter force the temperature of the exhaust gases to rise enough to burn the soot layers The regeneration process will not work properly when temperatures are low in winter for e...

Page 10: ...aintenance Depending on the working hours of the machine you should clean the machine and remove all deposits every six months Please follow these simple steps 1 Add 50 isopropyl alcohol to the water...

Page 11: ...wer 1200 kW HHO Gas Output Max 800 l h Max Pressure kg cm2 0 2 Max Water Consumption L h 0 20 Water refilling manual Water Tank Capacity 20 liters Autonomy 100 hours Dimensions L x l x h mm 400 x 500...

Page 12: ...EC Declaration of Conformity...

Page 13: ......

Reviews: