![HGST Ultrastar 7K2 Technical Reference Manual Download Page 17](http://html1.mh-extra.com/html/hgst/ultrastar-7k2/ultrastar-7k2_technical-reference-manual_2128580017.webp)
Ultrastar 7K2
HGST Hard Disk Drive Technical Reference Manual
17
Temperature and Humidity
Temperature & Humidity
Operating ambient temperature
1
5
C to 60
C
Max base casting temperature
2
60
C
S.M.A.R.T. temperature value
reported within ±3°C
Humidity
5-95% RH non-condensing
30
C (maximum wet bulb)
Thermal Gradient
20
C/hour (maximum)
Humidity Gradient
20%/hour (maximum)
Non-operating Temperature
-40
C to 70
C
Humidity
5-95% RH non-condensing
35
C (maximum wet bulb) for up to 21 days
3
Thermal Gradient
30
C/hour (maximum)
Humidity Gradient
20%/hour (maximum)
1
Ambient temperature is defined as the temperature of the environment immediately surrounding the drive.
The system environment must allow sufficient air flow to limit maximum surface temperatures as defined.
2
See Figure 2 Actual drive case temperature should be below 60°C and within the 5-60°C operating
ambient temperature.
3
Unless still in HGST’s factory sealed bag which allows up to 40
C without limit.
Temperature Measurement
Drive component temperatures measured at the drive baseplate thermocouple location must remain within
the limits specified in Table 4. Figure 2 shows the temperature measurement location. Sustained operation
at temperatures in excess of the reliability values degrades the MTBF rating. Short excursions up to, but not
exceeding, the maximum values will not affect the MTBF rating. Maximum component temperature ratings
must not be exceeded under any operating condition, or product warranty will be void.
Table 4 Maximum and Reliability Operating Temperature Limits (Drive Baseplate)
Component
Location
Maximum
Reliability
1
Drive baseplate
See Figure 2
60°C (140°F)
40°C
1
Sustained operation at temperatures in excess of the reliability values degrades the MTBF rating.
Figure 2 Drive Base Casting Thermocouple Location