for  wiring  are  485A,  485B.  The  transmission  medium  of  RS485  is  shielded  twisted  pair 
(STP).  And  the  RS485  interfaces  also  can  be  used  to  the  devices  maintenance  and 
upgrading. 
 
C. Energy Pulse Output Wiring Mode 

 

Energy Pulse Output (Pulse Constant is 9600): 
The terminal PE-/PE+ are used for active energy pulse output. 
 
D. Digital Input 
Digital Input (Extension function): wiring mode as shown below, the actual number of digital 
input depends on the actual energy meter model. 

 

Chapter 3 Meter Display and Basic Operation 

There are four buttons on the front panel, labeled H, P, E and V/A from left to right. It can 
be  used  for  displaying  different  measuring  data  and  setting  parameters  though  the  four 
buttons. 
Introduction:  Perform  the  following  button  operation,  the  meter  displays  the  measured 
parameters.  Different  module  of  energy  meters  have  different  display  items,  even  some 
items won’t be displayed. 
Therefore, the user should operate according to the specific conditions of the energy meters 
during use. 
 

Summary of Contents for DZ81-MS3UI5C

Page 1: ...DZ81 MS3UI5C Energy Meter User Manual V1 0 Heyuan Intelligence Technology Co Ltd...

Page 2: ...ered to have read this manual and accept all our terms Heyuan shall not be responsible or liable for any damages or injuries caused by improper meter installation and or operation Attention the follow...

Page 3: ...ifications 1 2 1 Dimension 1 2 2 Installation 1 2 3 Technical Parameters 1 2 4 Wiring 2 Chapter 3 Meter Display and Basic Operation 6 3 1 Parameters Display 6 3 2 Parameters Setting Operation 8 Chapte...

Page 4: ...metering 2 31 times harmonic analysis Display LCD Chapter 2 Specifications 2 1 Dimension unit mm Cut Out Size Unit mm Side View Unit mm 2 2 Installation unit mm This series of products should be inst...

Page 5: ...d Overload 1 2 times of the rated value Momentary Overload 2 times of the rated value Frequency 45 60Hz Functional Module Pulse output 1 Interface 1 RS485 Modbus communication protocol Baud rate 1200...

Page 6: ...ld be set as 2LL and the IL the current wiring mode should be set as 2C at the parameter setting interface 2 4 2 Power supply communication interface and Digital input A Power Supply The power supply...

Page 7: ...al number of digital input depends on the actual energy meter model Chapter 3 Meter Display and Basic Operation There are four buttons on the front panel labeled H P E and V A from left to right It ca...

Page 8: ...ine voltage and current circularly 2 Press button E it will display the values of energy parameters circularly Total Active Energy Total Reactive Energy 3 Press button P it will display the values of...

Page 9: ...nterface of metering data it will enter the system setting interface At the setting mode The button H is used for digital shift It can edit one digit shift left each time and the digit will be flashin...

Page 10: ...r the next setting interface Password Input Interfaces 2 Back light Time Setting BL interface is the page of backlight time setting At this page the user can see and set the backlight time the setting...

Page 11: ...ree Line open delta connection After the setting please press V A to confirm and enter the next setting interface Voltage Wiring Mode 6 Current Connection Method Setting IL is the current wiring mode...

Page 12: ...y is responsible for free maintenance or exchange within three year warranty period 3 The cost of the components and freight shall be charged for improper meter installation and or operation 4 Over th...

Reviews: