If the component is installed in server 1 and the server is installed in the Apollo r2600 Gen10 Chassis, bezel blanks
must be installed in drive bays 1-9 to 1-14. If the component is installed in server 3 and the server is installed in the
Apollo r2600 Gen10 Chassis, bezel blanks must be installed in drive bays 3-9 to 3-14. For more information, see
Installing drive blanks and thermal bezel blanks for components with thermal limitations
on page 23.
If the component is installed in server 1 and the server is installed in the Apollo r2800 Gen10 Chassis, the removable
blanks must be installed in drive bays 2-1 to 2-4. If the component is installed in server 3 and the server is installed in
the Apollo r2800 Gen10 Chassis, the removable blanks must be installed in drive bays 4-1 to 4-4. For more
information, see
Installing drive blanks and thermal bezel blanks for components with thermal limitations
on
page 23.
If the component is installed in server 1 and the server is installed in the Apollo r2800 Gen10 Chassis, bezel blanks
must be installed in drive bays 1-3, 1-4, 2-1, 2-2, 2-3, and 2-4. If the component is installed in server 3 and the server
is installed in the Apollo r2800 Gen10 Chassis, bezel blanks must be installed in drive bays 3-3, 3-4, 4-1, 4-2, 4-3 and
4-4. For more information, see
Installing drive blanks and thermal bezel blanks for components with thermal
on page 23.
FlexibleLOM adapters with SFP+, SFP28 or QSFP transceivers
Chassis
Fan configuration
Number of drives supported
by the server
Maximum inlet
ambient temperature
Apollo r2200 Gen10
Chassis
(12 LFF backplane)
Redundant and
nonredundant
5 to 6 drives
Optical cable: Not
supported
Copper cable: 30°C
(86°F)
5 to 6 drives
Optical cable: Not
supported
Copper cable: 28°C
(82.4°F)
0 to 4 drives
Optical cable: 28°C
(82.4°F)
Copper cable: 35°C
(95°F)
Apollo r2600 Gen10
Chassis
(24 SFF or 16 SFF
+ 8 NVMe
backplane)
Redundant and
nonredundant
0 to 10 drives
Optical cable: 28°C
(82.4°F)
Copper cable: 35°C
(95°F)
Apollo r2800 Gen10
Chassis
(24 SFF backplane
with SAS expander)
Redundant and
nonredundant
0 to 24 drives
Optical cable: 25°C
(77°F)
Copper cable: 35°C
(95°F)
Apollo r2800 Gen10
Chassis
(16 NVMe
backplane)
Redundant and
nonredundant
0 to 8 drives
Optical cable: 28°C
(82.4°F)
Copper cable: 35°C
(95°F)
The drive capacity must be less than 10 TB.
The drive capacity must be greater than or equal to 10 TB.
Specifications