Description
Chassis
Fan configuration
Number of drives
supported by the server
Maximum inlet ambient
temperature
Apollo r2800
Gen10 Chassis
(24 SFF backplane
with SAS
expander)
Redundant and
nonredundant
0 to 24 drives
30°C (86°F)
Apollo r2800
Gen10 Chassis
(16 NVMe
backplane)
Redundant and
nonredundant
0 to 4 drives
30°C (86°F)
Media Module 10
GB 2P 568FLR-
MMT
Apollo r2200
Gen10 Chassis
(12 LFF
backplane)
Redundant and
nonredundant
30°C (86°F)
Not supported
30°C (86°F)
Apollo r2600
Gen10 Chassis
(24 SFF or 16 SFF
+ 8 NVMe
backplane)
Redundant and
nonredundant
0 to 6 drives
30°C (86°F)
Apollo r2800
Gen10 Chassis
(24 SFF backplane
with SAS
expander)
Redundant and
nonredundant
0 to 24 drives
30°C (86°F)
Apollo r2800
Gen10 Chassis
(16 NVMe
backplane)
Redundant and
nonredundant
0 to 4 drives
30°C (86°F)
The drive capacity must be less than 10 TB.
The drive capacity must be greater than or equal to 10 TB.
If the component is installed in server 1 or server 2, and the server is installed in the Apollo r2200 Gen10 Chassis, drive blanks must be
installed in drive bays 1-2 and 2-2. Similarly, if the component is installed in server 3 or server 4, and the server is installed in the Apollo
r2200 Gen10 Chassis, drive blanks must be installed in drive bays 3-2 and 4-2.
Thermal limitations for components in systems with the Enhanced Processor
Performance feature disabled
Processors
The following limitations are for the Intel Xeon Gold 6244 (G6244) processor:
110
Specifications
Summary of Contents for HPE ProLiant XL170r Gen10
Page 6: ...Acronyms and abbreviations 128 6...
Page 22: ...22 Customer self repair...
Page 23: ...Customer self repair 23...
Page 24: ...24 Customer self repair...