HEUTE Solamat 400 Operating Instructions Manual Download Page 1

 

- 1 -

Industrial Sole Cleaning Devices  

 
Solamat 400

 / Art.-No. 065-4000   (dry) 

Solamat 450

 / Art.-No. 065-4500   (dry with suction) 

Solamat 500

 / Art.-No. 065-5000   (wet) 

 
 
 
 

Operating instructions   

 

 

 

          

State: 2008/11

 

 
 

Power supply: 

All machines will be delivered „ready for use“ with a standardized power connector. Please make sure 
that the power specification on the rating plate is consistent with your actual power supply (110 volt 
or 230 volt). 
 

Installation and putting into operation: 

The location needs to be roofed over and frost-proof in order to protect the machine and its electricity.  
For a secure stand the ground should be plane; rubber stripes may be used for levelling. 
After removal of packaging and protection provide for the aforementioned placement as well as power 
supply and the 

Solamat

 cleaning device will be ready for use. 

 

Solamat 450

 should be connected to the industrial vacuum cleaner which is available optionally. To 

do so, attach suction hose to the Solamat 450 and cleaner and put he power cord of the Solamat 450 in 
the power supply of the industrial vacuum cleaner. The cleaner itself will have to be connected to the 
mains and provides power to the Solamat 450 automatically. 
 
For 

Solamat 500

 please screw the drip-off grate to the main cleaning device and attach an ½“ water 

supply to the adapter (1 in picture 1) which leads to the magnetic valve.  
 

 

Picture 1 

 
A pressure of 3 to 5 bar can be applied to the water supply. The freshwater discharge can be regulated 
by means of the dial on the magnetic valve (2 in picture 1).  
 
Furthermore, a cleaning medium can be fed additionally with the 6 mm Ø hose (1 in picture 2 – 2 
feeds the cleaning medium to the brushes inside the machine). The throughput of this additional 
cleaning medium can be adjusted as well.  

Summary of Contents for Solamat 400

Page 1: ...t cleaning device will be ready for use Solamat 450 should be connected to the industrial vacuum cleaner which is available optionally To do so attach suction hose to the Solamat 450 and cleaner and p...

Page 2: ...3 and the protective cap of the feeding pump the feeding amount of the pump can be adjusted from 0 15 bis 4 5 l h with the regulator marked in picture 4 Picture 4 Make sure that the waste water hose p...

Page 3: ...ium to the brushes at the same time Abundant and dirty liquid is drained away from the sink via spillover towards the sewage hose Moving shoes and soles slightly on the brushes can improve the cleansi...

Page 4: ...leared via stopcock c f picture 5 regularly Afterwards close stopcock again and fill up freshwater and cleaning medium by activating the machine for as long as it takes to fill the bin up to the overf...

Page 5: ...ine from main power supply Unscrew the 4 screws of the steel cover and remove it entirely c f picture 3 Next loosen the 3 screws of the plain bearing holder slightly picture 10 but do not remove them...

Page 6: ...s described for the dry models Solamat 400 450 Picture 12 First remove the belt from the 4 pulleys next detach and remove plain bearing holder as described before but additionally remove the 5 screws...

Page 7: ...Warranty extends to 1 year months on electrical components and to 2 years on metal components commencing in each case on the day of dispatch from the supplier s premises or depot Changes or modificati...