Hettich Marketing- und Vertriebs GmbH & Co. KG · Vahrenkampstraße 12 -16 · 32278 Kirchlengern · Téléphone + 49 52 23/77-0 · www.hettich.com
Technik für Möbel
11
Hettich Marketing- und Vertriebs GmbH & Co. KG · Gerhard-Lüking-Straße 10 · 32602 Vlotho · T49 5733 798-0 · www.hettich.com
Hettich Marketing- und Vertriebs GmbH & Co. KG · Gerhard-Lüking-Straße 10 · 32602 Vlotho · T49 5733 798-0 · www.hettich.com
Operation manual
During the first start-up, there is a compulsory reset in order to be
able to commission the product.
The reset puts all columns on the same level. This ensures that the
table top is moved parallel to the basic level. In addition, the control
unit stores the connected components in the standard version.
If the actual table top position no longer matches the displayed
table top position or an already configured control unit is used with
another identical electrical height-adjustable workstation, you have
to perform an end position adjustment of the lowest table top posi-
tion.
1. Gently push and hold down the
Paddle
until the table stops at
the lower position limit.
2. Release the
Paddle.
3. Push and hold down the
Paddle
again
→
After about 5 seconds the table will move down slightly, then
up again
4. Release the
Paddle
.
→
The position reset procedure is complete.
If your control unit has been parameterized with additional
stopping points (e.g. a Container Stop Position), repeat
Step 3 until the table has moved upwards again.
4. Factory Reset (S 0 Reset)
With this function, you can reset the control unit to its factory
settings.
1. Disconnect the control unit from the mains.
2. While disconnected, press and hold the
SAVE Key.
3. Reconnect the control unit. Hold the Keys until the control unit
clicks
twice
per second.
4. Release the
SAVE Key
.
To be able to use the control unit again after changing a lifting
column‘s configuration in this way, proceed as follows:
1. Unplug the control unit‘s power supply and wait at least 5
seconds.
2. Plug the control unit‘s power supply back in again.
3. Carry out a manual reset (see section 7).
11