Page 1: ...1 SCAN LINE 40B AND 50B OPERATING INSTRUCTIONS DANISH DESIGN DANISH QUALITY DANISH PRODUCTION www heta dk EN...

Page 2: ...s than 175 cm2 which corresponds to a diameter of 150 mm If a damper is fitted in the flue gas pipe there must always be at least 20 cm2 of free pas sage even when the damper is in its specifications...

Page 3: ...may result in smoke being emitted from the stove when the door is opened The minimum chimney draft to ensure satisfactory combustion in stoves of this kind is 11 PA However there will still be a risk...

Page 4: ...re fore only burn clean dry wood in your stove Never use your stove to burn drifwood as this may contain a lot of salt which can damage both the stove and the chimney Similarly you must not fire your...

Page 5: ...ite very quickly i e in 30 seconds or 1 minute When the wood is burning with a steady flame close the start up mechanism Then adjust the secondary airflow to the level required For nomi nal operation...

Page 6: ...g If the stove it generating too little heat this may be because you are firing with wet wood In this case much of the heating energy is used to dry the wood resulting in poor heating economics and an...

Page 7: ...re delivery to the dealer Therefore the stoves are guaranteed against de fects in manufacturing FOR FIVE YEARS This guarantee does not cover Wearing parts fragile parts such as The fire proof bricks i...

Page 8: ...ough the floor The pipe must fit a flexible 100 mm hose The external air can be supplied to the stove both from below by removing the pre cut bottom or through the air intake hole in the bottom stone...

Page 9: ...e adjusting screws on the base up down We recommend installation of the soapstones is carried out by two people A standard set of brackets and pins are provided for installation of the soapsto nes Ref...

Page 10: ...10 10 x standard brackets 2 small pins see fig 2 12 x standard pins SCAN LINE 40B Scan Line 40B...

Page 11: ...e stone must be manually held in place until the handle is fitted Fig 3 The handle is fitted by placing it into the groove in the stone and the ash pan frame Adjust the handle so that is it placed in...

Page 12: ...there is smoke outlet behind Fig 3 The closed cover should be placed here unless the stove should be mounted with back outlet The open cover should be placed here Continue with sidestones as shown i...

Page 13: ...13 Scan Line 40B...

Page 14: ...14 Scan Line 40B...

Page 15: ...15 Scan Line 40B...

Page 16: ...16 Fig 6 Scan Line 40B Put brackets and pins in as shown fig 6 Continuing with the next row Start with sidestone backstone and then sidesto ne again Place brackets and pins Fig 7 Fig 7...

Page 17: ...rmastone can be installed in this stove The thermastone must be added after the soapstones have been placed and the stove firebox has been adjusted Continue with 3 row Again start with the sidestone a...

Page 18: ...ontinue with back stone and then a sideston Place brackets on top No pins are nessesary Fig 9 Finish with the topstone placein it loose on top If the stove has a top flue break of the inner ring Fig 1...

Page 19: ...19 Scan Line 40B Open Closed Regulate the convection air flow by turning the handle on the side of the stove...

Page 20: ...20 SCAN LINE 50B 14 x standard brackets 2 small pins see fig 2 20 x standard pins Scan Line 50B...

Page 21: ...e stone must be manually held in place until the handle is fitted Fig 3 The handle is fitted by placing it into the groove in the stone and the ash pan frame Adjust the handle so that is it placed in...

Page 22: ...there is smoke outlet behind Fig 3 The closed cover should be placed here unless the stove should be mounted with back outlet The open cover should be placed here Continue with sidestones as shown i...

Page 23: ...23 Scan Line 50B...

Page 24: ...24 Scan Line 50B...

Page 25: ...25 Scan Line 50B...

Page 26: ...26 Scan Line 50B Fig 6 Fig 7 Put brackets and pins in as shown fig 6 Continuing with the next row Start with sidestone backstone and then sidesto ne again Place brackets and pins Fig 7...

Page 27: ...thermastones can be installed in this stove The thermastone must be added after the soapstones have been placed and the stove firebox has been adjusted Continue with 3 row Again start with the sidesto...

Page 28: ...with back stone and then a sideston Place brackets and pins on the top Fig 9 Last row of soapstone is placed Start with the front stone then side stone then back stone and then the last side stone Pla...

Page 29: ...ne place it loose on top If the stove has a top flue break of the inner ring Fig 10 Finish with the topstone place it loose on top If the stove has a top flue break of the inner ring Fig 11 Top flue b...

Page 30: ...30 Regulate the convection air flow by turning the handle on the side of the stove Open Closed Scan Line 50B...

Page 31: ...31...

Page 32: ...32 12 12 2020 0037 1315 Version 2 1...