Installation
14
ATTENTION!
Safety notice of a hazard
The electrical installation of the digital inputs may
only be carried out by qualified specialist personnel.
ATTENTION!
Safety notice of a danger
The digital inputs are connected with an
external 12V dc power supply.
Failure to observe the voltage will damage
the device.
3.4.2 Connection of the digital inputs
The electrify eSat charging unit is equipped with an interface for digital inputs. With the digital
inputs, you have the option of reducing the charging power to 75%, 50%, 25% or issuing an
external charging release. The wiring of the individual inputs is shown in the graphic
below.
Connection drawing of the digital inputs
To use the digital inputs, use the cable adapter included in the scope of delivery. The
installation location is shown in the following illustration.
Plug connection of the digital inputs
1. Connector for digital input
2. Cable adapter for digital input
•
External charge release
IN1
•
Charging power 75%
IN2
•
Charging power 50%
IN3
•
Charging power 25%
IN4
Summary of Contents for eSat r20