Chapter 3 Device description
Operating manual HE 5710 / HE 5711
12
Version 1.3
3.2
Display and control elements
Fig. 3.2: Display and control elements (on the 5711 as an example)
Symbols
Meaning
1.
RUN
LED, green
Lights up if the operating voltage is being applied and the processor is active
2.
CYCLES
Coding switch
Determines the number of cycles (1 – 9). The setting 0 deactivates the cyclic
cleaning
3.
PULSE
LED, yellow
Lights up during the actuation period (pulse) of the valves
Potentiometer for pulsing period setting between 0.02 and 1.2 seconds
4.
PAUSE
LED, yellow
Lights up in the pause leading up to actuation of the next valve. The condition
of the control unit is recognisable, also for a longer pause time.
Potentiometer for pause time setting between 1 and 270 seconds
5.
Button TEST
The first press of the button starts the pulse and pause of the next valve.
The second press of the button interrupts the pause of the active valve or
starts the next valve.
Longer pressing of the button (for longer than 2 seconds) starts cleaning for
the set cycles. If the number of cycles is 0, cleaning will continue until the but-
ton is pressed again.
1
2
3
4
5