DESCRIPTION OF THE DEVICE AND TECHNICAL SPECIFICATIONS
Description of the device serie PN10:
1. Cable gland mains connection with connection cable
approx. 4.5 meters, ends open
2. Potentiometer (covered up);
(control cable with external control)
3. Mounting plates
4. Housing
5. Air inlet
6. Air outlet
Connection diagram
Type PN10-S:
L1
brown
N
blue
Type PN10-M 230 VAC and
400 VAC (2Ph):
L1
brown
N
blue
Type PN10-XL 400 VAC:
L1
black
L2
brown
L3
grey
Protective conductor
yellow/green
Technical data:
Air heater type
PN10 - S
PN10 - M
PN10 - XL
Voltage
VAC
230
400(2Ph)
480(2Ph)
230 400 (2Ph)
400 – 480
400 480
Frequency
Hz
50 / 60
Power
kW
2,3
3,3
3,7
4,6
5,9 – 8,5
11,8 – 17,1 17,0 25,0
Electricity
A
10,0 14,3
8,3
6,9
16,1
11,3
8,5 – 10,2 17,0 – 20,6 24,5 30,1
Max. temperature
°C/°F
600/1112
Min. air volume
l/min
280
420
360
490
560
950
1480
Max. pressure
bar
10
Weight Ø
kg
4,7
16,5
24,0
Air inlets Ø (female)
Zoll
½“
1“
2“
Blow off opening
(female)
Zoll
½“
1“
2“
Dimensions (L*W*H)
mm
321 x 160
445 x 285
582 x 340
Conformity symbol
Protection class I
!!! Please ask for special heating elements (power, voltage) !!!
MAINTENANCE
Check all cables for mechanical damage.