T-CONTROL
9
47
9.12.6
Solar
NOTE: At the solar module 5 resp. 6 (only at external solar module) program numbers are available, which
are set up by the service technician. The only differences of the programs are the integration and the number
of tanks (e.g. hot water tank, buffer). The hydraulic schemes of the different modules are described.
Navigation:
→
→
SOLAR
Screen:
By pressing the button:
the „Solar status“ menu will be displayed
the menu for the "settings" will be displayed
the menu for the "Aggregate-
Test“ will be displayed
the „solar yield“ menu will be displayed
Term
Description
Unit
Menu "Status"
Status 1
1
Collector flow
temperature
Indicates the collector flow temperature
°C
Collector back flow
temperature
Indicates the collector backflow temperature
°C
Tank 1 temperature
Indicates the temperature of tank 1
(e.g.: hot water tank, buffer)
°C
Tank 2 temperature
Indicates the temperature of tank 2
(e.g.: hot water tank, buffer) (only visible, if program 3, 4, 5 or 6 is
chosen)
°C
Collector pump
Indicates the status of the collector pump (On/Off)
-
Loading pump
Displays the condition of the backflow pump (On/Off)
-
Menu "Settings"
Settings
1
Pump trigger
Setting up the minimum collector temperature (15-70) to startup the solar
pump
°C
Tank 1 must
temperature
Setting up the set temperature (25-90) of tank 1
°C
Summary of Contents for firematic PELLET 120
Page 1: ...OPERATING INSTRUCTIONS Wood chips pellets heating system firematic PELLET 120 201 ...
Page 84: ...15 Annex 84 15 ANNEX 15 1 Additional boiler module Hydraulic recommendation 1 ...
Page 85: ...Annex 15 85 Hydraulic recommendation 2 ...
Page 86: ...15 Annex 86 15 2 Solar module Program 1 ...
Page 87: ...Annex 15 87 Program 2 ...
Page 88: ...15 Annex 88 Program 3 ...
Page 89: ...Annex 15 89 Program 4 ...
Page 90: ...15 Annex 90 Program 5 ...
Page 91: ...Annex 15 91 Program 6 ...
Page 92: ...16 Notes 92 16 NOTES ...
Page 93: ...Notes 16 93 ...