Herrmidifier G-100ES Installation Operation & Maintenance Download Page 10

8

Maintenance

To Inspect and Replace the Evaporator Pad:

It is recommended that the evaporator pad in the humidifier be replaced annually to
maintain efficient operation. However, more frequent replacement may be necessary in
areas of poor water quality. 

1.  Disconnect the power supply to the furnace.Turn OFF the water supply at the saddle

valve by turning the valve handle clockwise.

2.  Fully loosen the thumb screws at the bottom of the unit cover. The screws will remain

attached to the cover. To remove the cover from the duct, pull the bottom away and
then lift up. Put the cover aside for reassembly.

3.  Remove the water distribution tray, located above the evaporator pad. It is held in place

by a snap that must be lifted to pull out the tray.

4.  Pull the evaporator pad and frame assembly away from the duct, being careful not to

disturb the drain connection. Remove the old evaporator pad and discard.

5.  Inspect the interior of the humidifier and remove any mineral deposits and accumulation

from the frame assembly and drain tray.

6.  Remove the new evaporator pad from the plastic bag and insert into the frame assembly,

with the black spot facing up

. Ensure that no part of the evaporator pad is outside of

the frame. Return the evaporator pad and frame assembly to their original position
inside the humidifier.

7.  Check the distribution tray to ensure that holes are clear of any scale build up. If desired,

the distribution tray can be washed with mild detergent and warm water.

8.  Replace the distribution tray making sure the snap is hooked over the outside edge of

the tray. Replace the  cover and secure by  tightening the thumb screws. Turn the water
back on and reconnect power to the furnace.

End of Heating Season Shut Down:

1. Inspect and clean humidifier and components.

2. Turn water supply off at the solenoid valve.

3. Turn humidistat off.

Summary of Contents for G-100ES

Page 1: ...unt Humidifier Installation Operation Maintenance CAUTION READ INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS CAREFULLY FOR SAFE OPERATION EXERCISE EXTREME CAUTION WHEN WORKING WITH ELECTRICITY 2...

Page 2: ...ntents Introduction 1 Specifications 2 Capacity Selection Guide 3 Operation 3 Installation 5 Mounting Locations 6 Maintenance 7 Troubleshooting 9 Description of Parts 11 Parts List 12 Unit Diagram 13...

Page 3: ...at 71 to 72 F without controlled humidity Since every degree of temperature setback represents about 3 of your heating costs this can possibly represent a significant annual savings During the heatin...

Page 4: ...mer shut down Be sure to install a new evaporator pad at the beginning of the heating season before starting the humidifier Like your heating system and air conditioning unit periodic maintenance and...

Page 5: ...to control the flow of water by using the saddle valve It is designed to be either fully open or closed A felt pad located in the distribution tray distributes water evenly between the openings The d...

Page 6: ...for the desired conditions 30 40 Relative Humidity is typically recommended but it is important to reduce the setting whenever extreme low outdoor temperatures occur in order to avoid excessive conden...

Page 7: ...s using the auxiliary terminals interlocked to the furnace fan connect the primary of the supplied 120VAC 220 240VAC International to 24VAC transformer to the auxiliary terminals on the furnace Connec...

Page 8: ...on the return duct It is recommended that when the unit is installed in this location it is supplied with hot water service 2 If the furnace has an air conditioning coil be sure the unit does not inte...

Page 9: ...d be installed upstream of the conical mesh filter to reduce the frequency of cleaning Water softeners can be used to improve the quality of the supply water however deionized water is corrosive and c...

Page 10: ...l not to disturb the drain connection Remove the old evaporator pad and discard 5 Inspect the interior of the humidifier and remove any mineral deposits and accumulation from the frame assembly and dr...

Page 11: ...ould be an improper electrical installation The humidifier is designed to be used in conjunction with the furnace blower Q Water is constantly flowing out the humidifier drain and I am afraid that it...

Page 12: ...Corrective Action Replace the evaporator pad Clean or replace conical mesh filter and fluid restrictor Increase the humidity setting on the humidistat Turn the saddle valve handle in a counterclockwi...

Page 13: ...enoid valve Must be cleaned or replaced when water flow is impeded or humidification is reduced Evaporator Pad Allows water to evaporate as warm dry air is drawn through it Must be replaced on a regul...

Page 14: ...120VAC 24VAC Transformer 220 240VAC 24VAC Unit cover Water distribution tray Saddle valve assembly Humidistat Capacitor 120VAC Capacitor 220 240VAC 454275 002 251461 001 G 125 12 353226 001 G 116 6 G...

Page 15: ...13 Unit Diagram 1 2 3 4 8 9 10 11 12 13 14 15 16 7 17 5 6...

Page 16: ...edders com Humidifiers which have been installed or become part of real estate cannot be returned CareCo will receive freight prepaid only removable parts or components of such defective humidifiers 6...

Reviews: