8

 

Phone +49 4531 509-0 

 

Tightening torques 

  

max. tightening torque [Nm] 
Male thread 

Female thread 

Type 

Material  Thread 

NPT  R; Rc 

NPT  R; Rc 

06205 

CW614N 

1/4'' 

20 

20 

20 

  

  

  

3/8'' 

20 

20 

20 

  

  

  

1/2'' 

45 

45 

45 

  

  

  

3/4'' 

55 

55 

55 

  

  

  

1'' 

90 

90 

90 

  

  

  

11/4'' 

180 

180 

180 

  

  

  

11/2'' 

200 

200 

200 

  

  

  

1.4571 

1/4'' 

33 

33 

33 

  

  

  

3/8'' 

33 

33 

33 

  

  

  

06216/06217 
06218/06219 

CW617N 

1/2'' 

60 

100 

90 

  

  

  

3/4'' 

130 

180 

160 

  

  

  

1'' 

210 

340 

290 

  

  

  

11/4'' 

470 

560 

550 

  

  

  

11/2'' 

480 

730 

710 

  

  

  

2'' 

940 

1100 

1300 

  

  

  

06370 
06372 
06380 

CC491K 

1/2'' 

  

  

  

35 

80 

70 

3/4'' 

  

  

  

50 

110 

110 

1'' 

  

  

  

110 

250 

220 

11/4'' 

  

  

  

170 

390 

390 

11/2'' 

  

  

  

220 

550 

530 

2'' 

  

  

  

360 

890 

980 

CC480K 

1/2'' 

  

  

  

35 

80 

70 

3/4'' 

  

  

  

50 

110 

110 

1'' 

  

  

  

110 

250 

220 

11/4'' 

  

  

  

170 

390 

390 

1.4308 

1'' 

  

  

  

230 

490 

440 

06395 

CW614N 

1/2'' 

43 

70 

80 

49 

110 

90 

3/4'' 

120 

180 

160 

70 

180 

160 

1'' 

220 

340 

300 

150 

340 

300 

11/4'' 

550 

570 

560 

240 

570 

560 

1.4571 

1/2'' 

70 

70 

130 

70 

180 

150 

3/4'' 

200 

200 

280 

120 

290 

270 

1'' 

370 

380 

500 

250 

550 

470 

11/4'' 

920 

930 

940 

390 

910 

890 

1.4301 

1'' 

350 

380 

470 

  

  

  

11/4'' 

880 

910 

890 

  

  

  

CC491K 

1'' 

  

  

  

110 

250 

220 

11/4'' 

  

  

  

170 

390 

390 

11/2'' 

  

  

  

220 

550 

530 

2'' 

  

  

  

340 

880 

980 

06500 

CW614N 

11/4'' 

560 

  

  

  

  

  

11/2'' 

1100 

  

  

  

  

  

CC491K 

2'' 

  

  

  

370 

  

  

 
 
 
 

Summary of Contents for 06205

Page 1: ...HEROSE GMBH ARMATUREN UND METALLE Operating instructions Safety valve for industrial applications...

Page 2: ......

Page 3: ...oe Germany Phone 49 4531 509 0 Fax 49 4531 509 120 E mail info herose com Web www herose com 3rd issue 01 2020 The transmission or duplication of this document and the use or communication of its cont...

Page 4: ...Phone 49 4531 509 0 Table of contents 1 About these instructions 1 2 Safety 1 3 Transport and storage 3 4 Description of the safety valve 4 5 Assembly 7 6 Operation 9 7 Maintenance and service 10 8 Di...

Page 5: ...instructions see section 4 5 Media Operating conditions and applications deviating from these require the approval of the manufacturer Only media may be employed to which the materials used for the va...

Page 6: ...all work on the safety valve 2 5 Additional equipment and spare parts Additional equipment and spare parts not conforming to the manufacturer s requirements can negatively affect the operational safet...

Page 7: ...ibed protective equipment Secure the discharge area NOTICE Impermissible stresses arising from operating conditions and extensions added structures Safety valve body leaking or broken Provide suitable...

Page 8: ...n individual marking for identification Symbol Explanation e g G1 2 Connection size PN Rated working pressure max permissible operating pressure Manufacturer s mark HEROSE e g 1 4301 Material no e g 0...

Page 9: ...ticle 2 section 4 or the rules and standards of the American Society of Mechanical Engineers ASME Boiler and Pressure Vessel Code Section VIII Division I 4 4 Operational data Type d0 mm Pressure range...

Page 10: ...shipping offshore and industrial environments 50051 0011 Steams and gases 4 6 Materials See catalogue page 4 7 Scope of delivery Safety valve Operating instructions 4 8 Dimensions and weights See cat...

Page 11: ...stalled in a horizontal position 06602 06603 The safety valves can be installed vertically or in a horizontal installation position with the outlet facing downwards 50051 0004 Vertical 50051 0011 The...

Page 12: ...710 2 940 1100 1300 06370 06372 06380 CC491K 1 2 35 80 70 3 4 50 110 110 1 110 250 220 11 4 170 390 390 11 2 220 550 530 2 360 890 980 CC480K 1 2 35 80 70 3 4 50 110 110 1 110 250 220 11 4 170 390 390...

Page 13: ...mounting and installation work are completed Compare the material pressure temperature and installation position with the layout plan for the pipework system Dirt and residues have been removed from...

Page 14: ...uctions 7 2 1 Inspection and maintenance intervals Recommended intervals Inspection Interval Scope Inspection During start up Visual inspection of the angle valve for damage of the valving marking for...

Page 15: ...y or at all Attach water drain according to regulations Constantly blowing off Spring corroded by impermissible medium and broken Replace the safety valve System pressure too high Replace the safety v...

Page 16: ...ail service herose com Fax 49 4531 509 9285 8 Disassembly and disposal 8 1 Notices regarding the disassembly Take note of all national and local safety requirements The pipework system must be depress...

Reviews: