7
-4 Snap Qty(2) handles into Cable Collector.
HermanMlller
Renew"Table (Height Adjustable• Electrical)
7
.5 Install Cable Collector Ul w
i
th work surface using Tapping Screws 0N).
w
For Electric Tables
Initial Calibration
After assembly all electric tables must be calibrated to ensure smooth and trouble free
movement.
1.
Lower the table to the lowest height by pressing down on the paddle (or the down arrow
-
if
programmable switch)
2.
Continue to press & hold the control switch down until the table bottoms out the rises
slightly indicating it has been initiali
z
ed
.
Note
:
The table will readjust itself as needed
.
Follow
-
up Calibration
1. The table should be recalibrated if jerky or uneven movement is noted.
Container/Shelf Stop Directions - Simple Up/Down switch Setting
1.
Adjust table to the desired upper or lower limit desired.
2.
Find the black button underneath the switch, behind the paddle.
3. Hold the button for about
10
full seconds. Once the new stop has been initiated there will be
a double click sound.
The new upper or lower limit now has been set.
Void Limit
s
1.
Raise or lower the table to the new stop height.
2.
Repeat holding the button for
10
full seconds. There will be a single c
l
ick
.
The new stop location is now voided.
UL recommended load limit:
120
lbs.
To disengage control box from table either lower the HD wire tray, or use finger access hole
provided in the standard wire cover to remove cable management, then pull control box from
underside of work surface.
Part no. 1bc4vh rev F.