Assembly Instructions

2

1BLHZT rev B

3.1 Mark holes on wall and underside of surface.
3.2 Remove candilever assembly.
3.3  Drill 1/8” pilot holes using drill stop or tape set at a depth of 5/8” max. 
This ensure clearance into the Corian for the tip of the screw.
3.4  Drill 1/2” holes through drywall.  Make sure there are no utilities present. 
3.5 Insert wall anchors into holes.  Orient  toggles vertically. Secure to wall. 

2.1  After surface has been mounted on cabinets, position cantilever assembly 

under end of surface.

Machine  Screw

Tapping Screw

Toggle Bolt

4.1  Reposition cantilever assembly under surface. Check to make sure that it 
is still level.
4.2  Secure cantilever to wall with pan head machine screws provided with 
toggle bolt.
4.3  Secure cantilever to surface with 4 #10 - 5/8” pan head tapping screws 
provided with each bracket.

Step 2

Step 3

Step 4

Cantilever Assembly

Surface

Mark Holes

Mark Holes

Correct

Incorrect