GROUNDING INSTRUCTIONS
7235(9(17(/(&75,&6+2&.$1'
'($7+)520,1&255(&7
*5281',1*:,5(&211(&7,21
&KHFNZLWKDTXDOLILHGHOHFWULFLDQLI\RXDUH
LQGRXEWDVWRZKHWKHUWKHRXWOHWLVSURSHUO\
JURXQGHG'RQRWPRGLI\WKHSRZHUFRUGSOXJ
SURYLGHGZLWKWKHWRRO1HYHUUHPRYHWKHJURXQGLQJ
SURQJIURPWKHSOXJ'RQRWXVHWKHWRROLIWKH
SRZHUFRUGRUSOXJLVGDPDJHG,IGDPDJHG
KDYHLWUHSDLUHGE\DVHUYLFHIDFLOLW\EHIRUHXVH
,IWKHSOXJZLOOQRWILWWKHRXWOHWKDYHDSURSHU
RXWOHWLQVWDOOHGE\DTXDOLILHGHOHFWULFLDQ
Double Insulated Tools: Tools with
Two Prong Plugs
1. Tools marked “Double Insulated” do not
require grounding. They have a special
double insulation system which satisfies
OSHA requirements and complies with
the applicable standards of Underwriters
Laboratories, Inc., the Canadian Standard
Association, and the National Electrical Code.
2. Double insulated tools may be used in either of the
120 volt outlets shown in the following illustration.
6HH2XWOHWVIRU3URQJ3OXJ
2XWOHWVIRU3URQJ3OXJ
Extension Cords
1.
Grounded
tools require a three wire extension cord.
Double Insulated
tools can use either
a two or three wire extension cord.
2. As the distance from the supply outlet increases,
you must use a heavier gauge extension cord.
Using extension cords with inadequately sized wire
causes a serious drop in voltage, resulting in loss of
power and possible tool damage.
6HH7DEOH$
3. The smaller the gauge number of the wire, the
greater the capacity of the cord. For example,
a 14 gauge cord can carry a higher current
than a 16 gauge cord.
6HH7DEOH$
4. When using more than one extension cord to make
up the total length, make sure each cord contains at
least the minimum wire size required.
6HH7DEOH$
5. If you are using one extension cord for more
than one tool, add the nameplate
amperes
and use the sum to determine the required
minimum cord size.
6HH7DEOH$
6. If you are using an extension cord outdoors, make
sure it is marked with the suffix “W-A” (“W” in
Canada) to indicate it is acceptable for outdoor use.
7. Make sure the extension cord is properly wired
and in good electrical condition. Always replace
a damaged extension cord or have it repaired
by a qualified electrician before using it.
8. Protect the extension cords from sharp objects,
excessive heat, and damp or wet areas.
7$%/($5(&200(1'('0,1,080:,5(
*$8*()25(;7(16,21&25'692/7
1$0(3/$7(
$03(5(6
DWIXOOORDG
(;7(16,21&25'
/(1*7+
0 – 2.0
18
18
18
18
16
2.1 – 3.4
18
18
18
16
14
3.5 – 5.0
18
18
16
14
12
5.1 – 7.0
18
16
14
12
12
7.1 – 12.0
18
14
12
10
-
12.1 – 16.0
14
12
10
-
-
16.1 – 20.0
12
10
-
-
-
%DVHGRQOLPLWLQJWKHOLQHYROWDJHGURSWRILYHYROWVDW
RIWKHUDWHGDPSHUHV