![Hephzibah AIRREX AHSC-140 User Manual Download Page 14](http://html1.mh-extra.com/html/hephzibah/airrex-ahsc-140/airrex-ahsc-140_user-manual_2125525014.webp)
14
rev0
TROUBLE SHOOTING
TROUBLE
CHECK
REMEDY
NOT
WORKING
Power cable correctly connected
Connect cable correctly
Power button "OFF"
Press POWER button to "ON"
Blown fuse in electric panel
Replace fuse
Fuse (supply) blown
Exchange fuse in board
Breaker on switch board tripped
Check load capacity and reset
Ambient temp. too high
(Cooling & Dehumidifier: over 113
℉
Heating: over 81
℉
)
Use only below Cooling & Dehumidifier 113
℉
Heating 81
℉
POOR
COOLING
Filter blocked with dust
Clean Filter
Dust in heat exchanger
Clean heat exchanger
Obstacle against inlet side
Remove and allow 20"(50cm). clearance
Ambient temp. too high
(Cooling & Dehumidifier: over 113
℉
Heating: over 81
℉
)
Use only below Cooling & Dehumidifier 113
℉
Heating 81
℉