Henry Schein PS1 Operating Manual Download Page 1

®

900-3939

04

73

V

ET

P

IEZO

S

CALER

PS1

Distributed by:

Distribuido por:               Vertrieb durch:
Distribué par:                  Distribuito  da:

H

ENRY

S

CHEIN

I

NC

.

Melville, NY 11747 USA

Henry Schein U.K. Holdings Ltd.

Gillingham ME8 0SB U.K.

EC REP

www.henryscheinbrand.com

V

ET

P

IEZO

S

CALER

PS1

MADE IN CHINA

Fabricado en China

Fabriqué en Chine

Hergestellt in China

• Sistema ultrasónico para periodoncia e intervenciones mínimas restauradoras

INSTRUCCIONES DE USO

• Détartreur Piezo pour détartrage et Parodontologie

MODE D’EMPLOI

• HS-Ultraschallgenerator zur Zahnsteinentfernung und Paradontologie

BENUTZERHANDBUCH

• Ultrasonic scaler for use in periodontic and prevention treatments

OPERATING MANUAL

Copyright © 2009 by Henry Schein Inc.
All rights reserved. No part of these instructions may be reproduced or copied in any form by any means – graphic, electronic
or mechanical, including photocopying, typing or information retrieval systems – without written permission of Henry Schein Inc.

Todos los derechos reservados. Ninguna parte de estas instrucciones puede ser reproducida o copiada de ninguna manera y
por ningún medio – gráfico, electrónico o mecánico, incluyendo el fotocopiado, tipeo o los sistemas de recuperación de informa-
ción – sin la autorización expresa por escrito de Henry Schein Inc.

Tous les droits réservés. Aucune partie de ces instructions ne peut être reproduite ou copiée par aucun moyen – graphique, élec-
tronique ou mécanique, y compris la photocopie, la copie à main ou les systèmes de récupération de l’information – sans l’au-
torisation par écrit de Henry Schein Inc.

Alle Rechte vorbehalten. Dieses Benutzerhandbuch darf ohne schriftliche Genehmigung von Henry Schein Inc weder ganz noch
in Auszügen in jedweder Form- grafisch, elektronisch oder mechanisch- reproduziert oder kopiert werden, was Fotokopien,
Abschriften oder das Weiterleiten über andere Kommunikationsmittel einschließt.

Summary of Contents for PS1

Page 1: ...hanical including photocopying typing or information retrieval systems without written permission of Henry Schein Inc Todos los derechos reservados Ninguna parte de estas instrucciones puede ser reproducida o copiada de ninguna manera y por ningún medio gráfico electrónico o mecánico incluyendo el fotocopiado tipeo o los sistemas de recuperación de informa ción sin la autorización expresa por escr...

Page 2: ...ct is mainly used for teeth cleaning and is also an indis pensable equipment for tooth disease prevention and treatment The new product Vet Piezo Scaler PS1 has scaling endo automatic water supply function It contains the following features 1 Automatic frequency tracking ensures that the machine always works on the best fre quency and performs more steadily The optional function automatic water su...

Page 3: ... 250VT 1 6AL h Power source fuse 250VT 0 5AL i Water pressure 0 1bar to 5bar 0 01MPa to 0 5MPa j Weight of main unit 0 73kg k Weight of power source 1 2kg l Operating mode Continuous operation m Type of protection against electric shock Class II n Degree of protection against electric shock Type B equipment o Degree of protection against harmful ingress of water Ordinary equipment IPX0 p Protectio...

Page 4: ...t Foot switch socket Plug of foot switch Power supply Input voltage 220V to 230V Power cord plug Socket for power supply Power cord plug Connect pure water Cap of connector Water pipe Water entrance Switch for automatic water supply optional Air exit optional Connect water entrance small Connect air exit big ð ð ð ð Water entrance Reservoir Torque wrench 1 THEINSTALLATIONANDCOMPONENTSOFEQUIPMENT V...

Page 5: ...TION VET PIEZO SCALER PS1 c HandpieceThe main part of the whole handpiece can be autoclaved under the high temperature and pressure d The connector of the cable Connect the handpiece with the water source and power supply of the main unit Notice Keep the joint of handpiece and the cable connector dry 2 1 3 Instruction of using torque wrench showed in 1 4 1 f a The torque wrench s structure is desi...

Page 6: ...TENANCE VET PIEZO SCALER PS1 FAULT POSSIBLE CAUSE SOLUTIONS The power pipe plug is in loose contact The foot switch is in loose contact Insert the foot switch to its socket tightly Contact our dealers or us Contact our dealers or us Screw the tip on the handpiece tightly 1 4 1 f Contact our dealers or us Send it to our company to repair Contact our dealers or us Turn on the water control knob note...

Page 7: ... on the foot switch 4 1 4 The scaling tip must be fastened and there must be fine spray or drip coming out form the tip when operating 4 1 5 Change by a new one when the tip and ultrasonic file are damaged or worn excessively 4 1 6 Don t twist or rub the tip and endochuck 4 1 7 Don t use impure water source and be sure not use normal brine instead of pure water source 4 1 8 If use the water source...

Page 8: ...tation 4 4 3 Avoid solarization and getting wet in rain or snow during transportation We offer one year s free repair to the equipment according to the warranty card The repair of the equipment should be carried out by Henry Schein or an accred ited repair centre technician by Henry Schein We are not responsible for any irretrievable damage caused by a non accredited repair centre technician 4 PRE...

Page 9: ...len Endo automatisches Wasserversorgungs System optional und LED Funktionen optional Es beinhaltet die folgenden Eigenschaften 1 Das automatische Verfolgen von Frequenzen stellt sicher dass das Gerät immer im besten Frequenzbereich und gleichmäßig arbeitet Optionale Funktion Automatisches Wasserversorgungs System MAGENTA OUT 2 Das Handstück ist abnehmbar und kann bis zu einer Maximaltemperatur von...

Page 10: ...sgangsleistung 3W bis 20W g Sicherung Hauptgerät 250VT 1 6AL h Sicherung Leistungsquelle 250VT 0 5AL i Wasserdruck 0 1 bar bis 5 bar 0 01MPa bis 0 5MPa j Gewicht Hauptgerät 0 73kg k Gewicht Leistungsquelle 1 2kg l Betriebsart Dauerbetrieb m Art des Schutzes gegen Elektroschock Klasse II n Grad des Schutzes gegen Elektroschock Typ B Ausrüstung o Grad des Schutzes gegen gesundheitsgefährdenden Zuflu...

Page 11: ...hse Fußschalter Stecker Fußschalter Netzteil Eingangsspannung 220V bis 230V Stecker Stromkabel Buchse Stromanschluss Stecker Stromkabel Destilliertes Wasser onnect pure water Anschlusskappe anschließen Wasserschlauch Wassereingang Schalter für automatische Wasserversorgung optional Luftausgang optional Wassereingang klein anschließen Luftausgang groß anschließen ð ð ð ð Wassereingang Reservoir Dre...

Page 12: ...nter hoher Temperatur und Druck autoklaviert werden d Kabelsteckverbindung Schließen Sie das Handstück an die Wasserversorgung und Energieversorgung des Hauptgeräts an Hinweis Halten Sie das Anschlussstück des Handstücks und die Kabelsteck verbindung trocken 2 1 3 Anleitung zur Benutzung des Drehmomentschlüssels gezeigt in 1 4 1 f a Die Struktur des Drehmomentschlüssels ist so angelegt dass die St...

Page 13: ...werden kann nehmen Sie bitte Kontakt zu Ihrem Händler oder Hersteller auf 3 STERILISIEREN UND WARTUNG VET PIEZO SCALER PS1 FEHLER MÖGLICHE URSACHE LÖSUNGEN Der Netzstecker steckt nicht richtig in der Steckdose Der Fußschalter ist nicht richtig eingesteckt Stecken Sie den Fußschalter richtig in die Dose Kontaktieren Sie uns oder unsere Händler Kontaktieren Sie uns oder unsere Händler Schrauben Sie ...

Page 14: ...ußschalter betätigen 4 1 4 Die Scale Spitze muss fest sitzen und ein feiner Sprühstrahl oder Tröpfchen müssen während der Bedienung aus der Spitze kommen 4 1 5 Bitte wechseln Sie die Spitze und Ultraschall Feile aus wenn diese beschädigt oder extrem abgenutzt sind 4 1 6 Verbiegen oder polieren Sie die Spitze und das Endo Bohrfutter nicht 4 1 7 Benutzen Sie kein unreines Wasser oder gewöhnliche Lau...

Page 15: ...ansportieren Sie das Gerät nicht zusammen mit Gefahrgütern 4 4 3 Vermeiden Sie während des Transports Sonneneinstrahlung und Feuchtigkeit durch Regen oder Schnee Gemäß der Garantiekarte bieten wir ein Jahr gratis Reparaturen für dieses Gerät an Reparaturen am Gerät sollten durch unseren Fachtechniker durchge führt werden Wir sind nicht verantwortlich für irreversible Schäden die durch Nicht Fachle...

Reviews: