Henny Penny PFE-500 Instruction Manual Download Page 6

 

to keep clean and sanitary and enhance the use life span of the machine.

 

 

3.

 

After a relatively long time use, the rubber gasket shall be replaced in time if it is found aging and 

ineffective.  Loosen  the  glue  bar  fastening  screws  of  four  sides  on  the  cover,  take  out  the  glue  bar 

from the groove slowly, put new sealing rings into the groove, and 

fasten the screws. 

4.

 

The machine is  equipped with  overheating protector. 

If the temperature controller is out of 

work  and  the  oil  temperature  is  up  to  250

,  temperature  limiter  can  cut  off  the  heating  power  to 

make  sure  of  the  safe.  Operator  should  check  the  reason  for  overheat  and  try  to  get  rid  of  it.  If 

needed, you should press the reset key in the “temperature limiter” to restart the machine. 

 

 

 

TROUBLESHOOTING 

No  problem 

Cause   

Machine not work       

Check the electric power on or off, see the fuse whether burn, 

miss phase or neutral wire not install well. If it is not connect 

well, reset it. 

Not Heating 

1.Check  the  contactor  and  make  sure  whether  is  ok,  if  not, 

reconnect it. 

2.Check the timer, if it is not ok, adjust it or reset it 

3.Check  the  panel  and  make  sure  whether  it  is  ok,  check  the 

temperature sensor , adjust it or reset it. 

Heating slowly   

1.Check the heating elements, if it is not connected well, adjust 

it. 

2. Check the heating elements by Multi-meter,   

Not 

controlling 

 

temperature 

automatically 

Check the Temperature sensor, if it is not ok, adjust it , mend it 

or reset it. 

Not Timing 

Check  the  timer  working  or  not,  if  not,  adjust  or  change  the 

time controller 

Operating pressure too high 

Check the Deadweight valve, open it and clean it. 

Pressure  Gauge  is  not  working  or 

pressure is below the specified working 

pressure 

1.Check the pressure gauge, if it is ok good, change a new one. 

2. Check the Solenoid valve closed or not closed well, Close it 

tightly. If it is closed well, you should change a new solenoid 

valve. 

3.Check the deadweight valve, to make sure the screw inside is 

well, if not, change a new one. 

  4.If the lid is leakage gas, you should change the seal rubber 

or adjust it. 

Over  temperature  and  it  can’t  be 

restarted. 

After trouble clearing, press the rest key of temperature limiter. 

 

Reviews: