In figure 13 you see the connected sensors – in this case 6 sensors. The evaluation
unit has determined rope 2 as the reference rope. (during the total adjustment proce-
dure channel 2 will never display a deviation; If you adjust rope 2 this has on the dis-
play only effects on the other measuring channels). It is not necessary that you adjust
this reference rope. After adjustment of all other ropes this will automatically bear the
correct load. All other ropes have to be adjusted in such a way that the relevant verti-
cal bar becomes minimal or can no longer be distinguished from the centre line, re-
spectively, (ideal setting) or it is positioned within the tolerance field that you have
determined, marked by the broken horizontal lines.
As soon as all ropes have been adapted with the desired accuracy you may leave
the rope load wizard by pressing "OK".
Figure 14: Storage of the rope load setting
After completion of the rope adjustment the question is displayed whether the rope
load wizard shall save a record of this adjustment process (see Figure 14). Apart
from time and date this storage records the loads of the ropes before and after the
adjustment. Press the
YES
button in order to store a record of the adjustment carried
out. If you decide against data logging, press the
NO
button. Using the button ID you
can assign a 16 digit alpha-numerical designation to the record, in order to easier find
the measurement again In both cases you return to the main display. In the internal
memory of the MSM12 you can store up to 100 adjustment records.