Henley Stoves BIO 80 Maintenance And User Manual Download Page 1

 

 
 

 

Maintenance and User Manual 

Pellet Stove 

 
 
 

 

 

BIO 80 

BIO 80Q 

 
 
 
 

IMPORTANT! 

This Appliance must be fitted by a HETAS / METAC Qualified Installer 

 
 

 

Summary of Contents for BIO 80

Page 1: ...Maintenance and UserManual Pellet Stove BIO 80 BIO 80Q IMPORTANT This Appliance must be fitted by a HETAS METAC Qualified Installer...

Page 2: ...allow a very low noise level Automatic temperature control The internal thermostat senses the temperature environment and maintains it constant according to the settings inserted Control display The...

Page 3: ...failure to respect these instructions This stove should be used for the purposes for which it was designed and made The manufacturer is excluded from any contractual or extra contractual liability for...

Page 4: ...heck the size of your room is not larger than what is recommended for maximum sizes a 7 7kW will sufficiently heat We recommend referring to an online stove output to room size calculator to help you...

Page 5: ...there is smoke will cause further smoke to build and not be extracted What setting should I use when starting my pellet stove Upon each use It is highly recommended starting with Level 1 with a tempe...

Page 6: ...emoved when an appliance is replaced unless proven to be recently installed and in good condition The installation of manual draft adjustment devices on forced draft appliances is not permitted The mi...

Page 7: ...raught which is necessary for the different models of pellets stoves is 8pa to 12pa 0 08 to 0 12mbar Point where the flue passes through weather surface Note 1 2 Clearances to the flue outlet A At or...

Page 8: ...t 1m above the highest point of contact of chimney and roof Where the roof has a pitch of more than 10 on both sides and the outlet is at the ridge or within 600mm of it the height of the chimney or f...

Page 9: ...metically sealed doors and windows The situation can also be problematical when on the other hand there are drafts inside the room generated by fans in the kitchen or bathroom for example To avoid thi...

Page 10: ...m thickness 0 5mm with a diameter of 80 mm or 100mm depending on the type of plant see picture 2 pag 6 you cannot use pipes made of asbestos cement or flexible metal The pipes must be sealed with high...

Page 11: ...e only combustible material you can use You can find different kind of pellets with different characteristics and quality on sale We recommend using pellets of superior quality as that has major influ...

Page 12: ...methods there must be a minimum distance of at least 20 cm from flammable objects sofas furniture wooden covering to the back and side of the stove and of 80 cm to the front where the fire door is If...

Page 13: ...or 2 3 days display A will show the number 3 so that the mechanical parts are able to settle into smooth running IMPORTANT Continuous operation of the stove at maximum power may shorten the expected l...

Page 14: ...t shows the state of the stove During functioning it shows the temperature chosen by the user During input setting it shows the parameter you are changing Starting To start the stove keep key P4 press...

Page 15: ...play B Fumes gas temperature To verify the fumes gas temperature at the outlet keep key P1 pressed for few seconds Switching off To switch off the stove keep P4 pressed Clean final will be displayed D...

Page 16: ...ON for example h 17 00 and turn OFF for example h 21 00 Press set P3 to confirm each time The situation could be the following Daily Program Start 1 Stop 1 Start 2 Stop 2 ON h 6 30 h 10 30 h 17 00 h 2...

Page 17: ...s in order to avoid any crossover with weekend program M2 4 Go into setting M2 4 press set P3 decide ON OFF then confirm with set P3 If you decide ON the green light will switch ON This green light wi...

Page 18: ...the stove in summer mode the display will show Ven flanked by the value of the power while in winter mode will display Start Optional remote control With the remote control it is possible to adjust t...

Page 19: ...al 3 Hot Exhaust will appear on display the pellets stoking is decreased and the card makes the fumes extractor work at its minimum speed to take the temperature back to the setlimits If temperature...

Page 20: ...assistance for the maintenance to a qualified professional Do not do it can cause damage to the heater and its electrical and mechanical parts thereby affecting the operation safety and validity of th...

Page 21: ...lour if it is red that means it is weak if there is black smoke that means the brazier is dirty and it must be cleaned Ash draw cleaning Pic 14a IMPORTANT When refitting brazier ensure the above side...

Page 22: ...3 Average temperature fumes 92 5 167 C Mass flow fumes 2 9 5 5 g s Tank capacity 15 kg Volume to heat 150 240 m3 Air flow max 190 m3 h Autonomy 10 26 h Air fumes tubes diameter 40 80 mm Electrical inp...

Page 23: ...Average temperature fumes 92 5 167 C Mass flow fumes 2 9 5 5 g s Tank capacity 15 kg Volume to heat 150 240 m3 Air flow max 190 m3 h Autonomy 10 26 h Air fumes tubes diameter 40 80 mm Electrical input...

Page 24: ...BIO Pellet Stoves 23 Wiring diagram N100 For the correct operation of the stove respect the polarity of the thermo couple...

Page 25: ...tions of the air inlet on the back of the stove brazier grid holes obstructed and or brazier box with too much hash exchanger pipes too dirty clean the extractor blades and its scroll see Maintenance...

Page 26: ...ll the tank Clean the brazier see Maintenance Empty the brazier and start again if the problem continues call a specialised technician Replace the plug Call a specialised technician Restart the stove...

Page 27: ...ot Have it cleaned immediately Pellets can burn thanks to the chimney flue depression without the aspirator Have it replaced immediately as it can be bad for your health Call a specialised technician...

Page 28: ...tificate which should be completed correctly and accompanied by the receipt of purchase as proof The apparatus is not guaranteed in any way for non domestic use The same applies in the event that the...

Page 29: ...ise you to always refer to the dealer who sold the apparatus to you or to our nearest Technical Servicing Centre specifying the model and serial number and describing the problem Also bear in mind tha...

Page 30: ...Centre Work done on Specialised Technical Servicing Centre Material used Guarantee YES NO YES NO YES NO YES NO User s signature Segnature of TSC Material used Guarantee YES NO YES NO YES NO YES NO Us...

Page 31: ...Centre Work done on Specialised Technical Servicing Centre Material used Guarantee YES NO YES NO YES NO YES NO User s signature Segnature of TSC Material used Guarantee YES NO YES NO YES NO YES NO Us...

Page 32: ...BIO Pellet Stoves 31...

Page 33: ...BIO Pellet Stoves FAIR srl Via Lago di Costanza 24 Z I 36015 Schio Vicenza Italia Tel 39 0445 698000 Fax 39 0445 698100 www fair europe com info fair europe com Copyright Fair Rev 6 14 02 2019 EN...

Reviews: