- 6 -
Check-weighing mode setting:--
press
:
z
HI(upper )/ Lo(lower)/ In(during
upper value to lower value) /un
( outside the value)/ 3b( 3 point)/
oK( 1 point) /oFF(close)
z
(totally we have 3 value to set. For
example, if you set 3kg for HI, and
1kg for LO, and 2kg for OK, then if
you want it warning when upper than
3kg, then you choose HI, if you want
it warning when lower than 1kg, then
you choose LO, if you want it
warning when during 1kg-3kg, then
you choose IN, if you want it warning
when upper than 3kg and lower than
1kg, then you choose Un, if you
want it warning just in 3kg, 2kg, and
1kg, then you choose 3b, if you want
it warning in 2kg, then you choose
OK, if you do want any warning, then
you choose OFF.)
press
to select in turn
Check-weighing memory setting
:
--
press
:
z
M.On / M.oFF
(“M.On” means check-weighing
memory is open; “M.oFF” means
check-weighing memory is closed)
press
to select in turn
press
and
to eliminate
check-weighing
RS232 output format setting
:
--
press
:
z
Prt.Pr -data sent when key
Pressed(can do date send in dual
direction, see page 22)
z
Prt.Co- data sent continuously
z
Prt.St-data sent auto matically when
stable symbol show
press
to select in turn