Seite1/7 

Sach-Nr. 2 727 022 Version 1250899MW

operating instructions

signo 727 SSI

Position-Indicator with/without limit
values and SSI input from absolute
encoder

1. Safety instructions

This instrument has been built and tested in
accordance with EN 61010, part1 - Protection
Measures for Electronic Measuring Instruments -
and have left our works in safe and proper condition.
In order to maintain these conditions and to ensure
safe operation, the user must observe the
instructions and warnings provided in these
operating instructions.
• This units must only be operated if correctly

installed!

• The supply voltage must be derived from a SELF

SOURCE (12-24VDC versions) according to EN 60
950, since no galvanic separation is provided
between power-supply and electronic in-/outputs!

• When mounting and installing the units, the

instructions of the local suppliers of  energy are to
be considered.

• The unit must only be opened for setting by trained

personnel.

• The plug-in terminals, at rear of the unit, must not

be accessed before first isolating the supply.

• The identification numbers of the plug-in terminals

and of the corresponding socket strip must be
observed.

• Unassigned terminals (NC) may not be connected!
• Connection terminals are to be protected by

installation!

Contents

1. Safety instructions

1

2. Mounting of the position indicator

2

2.1  Mounting and dimensional drawing

2

2.2.1 Connections

2

2.2  Terminal connections

2

2.2.2 Description of inputs and outputs

3

2.3  Description of function of position

indicator 

3

3. Operation of the position indicator

3

3.1  Display and keyboard

3

3.2  Setting the reference value and resset

of the chain value

3

3.3  Changing limit value 1and 2 and set

value

4

4. Programming

4

4.1  Survey

4

4.2  Display of the absolute data of the

absolute shaft encoders 

5

4.3  Changing system parameters

5

4.4  Survey on the system parameters

and alternatives

5

5. Locking of keyboard functions

6

6. Failures and error messages

6

7. Technical data

6

7.1  Ordering information 

7

7.2  Accessories

7

7.3  Explanation of technical terms

7

• In order to ensure hand contact safety at the

connection terminals, live wires must be con-
nected properly to the connection terminals.

• If safe operation can no longer be ensured, the

position indicator must be disabled and secured
against accidential operation.

• Installation of electrical devices should only be

carried out by a qualified electrican.

• Panel mounting devices should only be operated

when proberly mounted in the panel

• Before switching on, make sure that the power and

control voltages do not exceed the values specified
in the technical data.

• In a situation where failure of the device could

cause harm to people, animals or property,
additional safety measures must be employed,
e.g. stop switches, protection devices etc.

• Hengstler counters are intended for industrial

applications.

• The mounting and environment and nearby cabling

have an important influence on the EMC (noise
radiation and noise immunity) of the counter.
When putting into operation, the EMC of the whole
installation (unit) has to been secured. In
particular, the relay outputs are to be protected
from high noise radiation by suitable wiring.

Summary of Contents for signo 727 SSI

Page 1: ...function of position indicator 3 3 Operation of the position indicator 3 3 1 Display and keyboard 3 3 2 Setting the reference value and resset of the chain value 3 3 3 Changing limit value 1and 2 and set value 4 4 Programming 4 4 1 Survey 4 4 2 Display of the absolute data of the absolute shaft encoders 5 4 3 Changing system parameters 5 4 4 Survey on the system parameters and alternatives 5 5 Loc...

Page 2: ...place 4 Fix the position indicator with the screws against the panel 2 2 Terminal connections Attention Take care that all parts of system are deenergized during the installation of position indicator and that current is not switched on during assembly Safety conditions are to be observed during installation which shall be effected by trained personnel only Caution The operation and or switched vo...

Page 3: ...ter 4 3 Application input Terminal 25 set value refernce point display hold or chain reset can be programmed see chapter 4 3 2 3 Description of function of position indicator The position indicator is working in range mode i e the output signals Out 1 and Out 2 are set when reaching the respective limit value The bistable signal is active until the count value falls below the limit value or the co...

Page 4: ...de Exit without storage by time criterion the return to the display mode is automatically done 15 sec after the last pressing of a key without storing the changed parameter 4 Programming 4 1 Survey level 1 SET Setvalue long 2s Power ON and simultaneous P1 limit value 1 P2 limit value 2 short key to switch to the remarks next parameter DISPLAYMODE Normal Count Mode simultaneous simultaneous short l...

Page 5: ...ec after a key has been pressed last without the changed parameter being stored 4 4 Survey on the system parameters and alternatives Parameter Display Alternatives Signification total encoder resolution bit F1 1 to 24 total encoder resolution in bits encoder resolution single turn bit F2 0 to 12 resolution of the singleturn part in bits Data coding F3 bin Gray binary code gray code Data transfer f...

Page 6: ...it value 2 plus limit value 1 Example limit value 1 20 limit value 2 100 absolute OUT1 at 20 OUT2 at 100 relative OUT1 at 80 100 20 OUT2 at 100 5 Locking keyboard functions In level 3 the following keyboard functions can be locked Calibration function entry to level 1 entry to level 2 buttons F1 and F2 The setting of those keylocks is explained in chapter 4 3 6 failures and error messages failure ...

Page 7: ...put Values Relay Output Terminals 6 8 and 10 12 OUT 1 OUT 2 Contact Type changeover relay Contact Guard Circuit no externally recommended for capacitive and or inductive loads Switching Voltage max 30 VDC 250 VAC min 5 V AC DC Switching Current max 1 A min 10 mA Relay Response Delay 15 ms Transistor Output terminals 14 15 Switching voltage PNP 24VDC at AC supply VDC 2V at DC supply Switching curre...

Reviews: