User Manual for Cutter Type L
0 685.74
2685741
Modification No.: 4180901CK1
Page 3 of 4
Technical Data
External start pulse by
SPDT contact
Triggering pulse length
≥
100 ms,
≤
150 ms
Cutting cycle max. (full cut/partial cut)
350 ms
Operating voltage V
B
12 VDC/24 VDC (SELV)
Voltage tolerance
±
10 %
Current
(at T
u
= 20°C)
V
B
= 12 V:/ V
B
= 24 V:
Making current
2,4 A / 1,2 A
No-load current
0,24 A / 0,12 A
Cutting current
1,0 A / 0,5 A
Failure
(e.g. blocked knife)
2,4 A / 1,2 A
1)
Climate
operating temperature
storage temperature
medium relative humidity
-10 ... + 60°C
-40 ... + 70 °C
65% without condensation
Service life
(number of cuts)
1,0 Mio with linerless material up to 100 g/m²
2)
Noice emission
distance 30 cm, V
B
+ 10 %
General design
75 dB (A)
as per EN 60950, protection class III
Protection class
(IEC 529)
IP 10
Vibration performance
(IEC 68-2-6)
10 ... 60 Hz; 0,7 mm p.p.
60 ... 500 Hz; 50 m/s
2
,
Shock resistance
(IEC 68-2-27)
800 m/s²; 6ms
Drop test
(DBP DIN ISO 2206, 2233, 2248)
passed
Mounting
2 hubs and 2 plastic inlets for M3 screws
Paper
: Linerless material: 98 g/m²/ 101
✙
✙✙
✙
m
(REI 1400)
channel width (L)
63 mm; 90 mm and 118 mm
paper width
≤
60 mm,
≤
87 mm,
≤
114 mm
paper weight
60 ... 100 g/m²
Dimensions
85 x 67 x 21 mm; 112 x 69,5 x 24 mm;
140 x 69,5 x 24 mm
Weight
ca. 160 g; ca. 320 g; ca. 360 g
Electrical connection
flat ribbon cable with five cores and JST-plug
1)
If the motor is jammed, the safety switching supplied by the customer must ensure that the power applied to the motor is limited after approx. 10 seconds.
2)
Linerless material: 98 g/m² / 0,1 mm; REI 1400