Helvar
|
Helvar Oy Ab, Keilaranta 5 FI-02150 Espoo, Finland. Data is subject to change without notice. www.helvar.com
0
5
10
15
20
25
30
35
40
45
50
55
60
0,00
0,20
0,40
0,60
0,80
1,00
1,20
1,40
Ou
tp
ut v
ol
ta
ge
[V
]
Output current [A]
Whole dimming range
available (2 - 100 %)
Dimming range depending
on set current
U
LED
(max), V
U
LED
(min), V
Operating window
Driver performance
Operating Conditions and Characteristics
Absolute highest allowed t
c
point temperature
75 °C
Tc life (50 000 h) temperature
75 °C
Ambient temperature range
–
25 °C
...
+45 °C*
Storage temperature range
–
40 °C
...
+80 °C
Maximum relative humidity
No condensation
Life time(90 % survival rate)
100 000 h, at t
c
= 65 °C
70
000
h,
at
t
c
= 70 °C
50
000
h,
at
t
c
= 75 °C
*) For other than independent use, higher t
a
of the controlgear possible as long as highest allowed t
c
point temperature is not exceeded
1) From 500 mA to 1200 mA, full dimming range ( 2 % - 100 %) and wide CCT dynamic range available in the whole
area. Each single channel can dim down to 0.1 % level.
2) From 100 mA to 500 mA, the absolute minimum dimming level is limited to 10 mA of total current. Dimming / CCT
control possible all the way down to that current (dimming range 10 % - 100 % at 100 mA), but the dynamic range may
be limited. Each single channel can dim down to 0.5 mA level.
1)
2)
50,0
55,0
60,0
65,0
70,0
75,0
80,0
85,0
90,0
95,0
0
5
10
15
20
25
30
35
40
45
50
55
Effic
ie
nc
y
(%
)
Total output power (W)
Typical efficiency
1200 mA
350 mA
0,60
0,65
0,70
0,75
0,80
0,85
0,90
0,95
1,00
0
5
10
15
20
25
30
35
40
45
50
55
λ
Total output power (W)
Typical power factor
1200 mA
350 mA
18.02.2022 2/7
LL50iC-DA-100-1200
T22 159 1B