Helvar
|
Helvar Oy Ab, Keilaranta 5 FI-02150 Espoo, Finland. Data is subject to change without notice. www.helvar.com
LC60DS-DA-700-1400 LED driver is suited for built-in usage in luminaires. With external strain relief (LC-SRC) independent use is possible
too. In order to have safe and reliable LED driver operation, the LED luminaires will need to comply with the relevant standards and
regulations (e.g. IEC/EN 60598-1). The LED luminaire shall be designed to adequately protect the LED driver from dust, moisture and
pollution. The luminaire manufacturer is responsible for the correct choice and installation of the LED drivers according to the application
and product datasheets. Operating conditions of the LED drivers may never exceed the specifications as per the product datasheet.
Installation & operation
Maximum ambient and t
c
temperature
:
• For built-in components inside luminaires,
the
t
a
ambient
temperature range is a guideline given for the optimum
operating environment. However, integrator must always
ensure proper thermal management (i.e. mounting base of the
driver, air flow etc.) so that the
t
c
point temperature does not
exceed the
t
c
maximum limit in any circumstance.
• Reliable operation and lifetime is only guaranteed if the
maximum t
c
point temperature is not exceeded under the
conditions of use.
Current setting via dip-switch
LC60DS-DA-700-1400 LED driver features a constant current output
adjustable via Dip-switch combinations
• For the combination/current values, refer to the table on page 4.
Emergency use
• The product can be continuously operated only with AC, the DC is
reserved only for emergency usage.
Miniature Circuit Breakers (MCB)
• Type-C MCB’s with trip characteristics in according to EN 60898
are recommended.
• Please see more details in “MCB information” document in each
driver product page in “downloads & links” section.
Installation site
• The general preferred installation position of LED drivers for
independent use is to have the top cover facing upwards.
Lamp failure functionality
No load
When open load is detected, driver goes to standby and recovers
through mains reset.
Overload
When overload is detected, driver goes to standby mode and recover
after mains reset.
Short circuit
Driver can withstand output short circuit and after resolving the
fault, driver recovers after mains reset.
Push to Fade
Push to Fade solution includes additional fading behavior, which
provides smooth transition between on and off states. Please note
that Push to Fade is not compatible to be installed in the same circuit
with Helvar Switch-Control or Switch-Control 2 devices.
Always before installation and for troubleshoot and guidance,
refer to the user guide at www.helvar.com.
Use of Push to Fade functionality
• Maximum numbers of LED drivers to be connected to one
switch is 30.
• Ensure that all components connected to Push to Fade circuitry
are mains rated.
• The transition between 0 to 100% (when turned ON / OFF) is ~
1 second.
Conformity & standards
General and safety requirements
EN 61347-1: 2015
Particular safety requirements for DC
or AC supplied electronic control gear
for LED modules
EN 61347-2-13: 2014 +
A1: 2017
Additional safety requirements for AC
or DC supplied electronic controlgear
for emergency lighting
EN 61347-2-13: 2014 +
A1:2017, Annex J
Thermal protection class
EN 61347, C5e
Mains current harmonics
EN 61000-3-2: 2014
Limits for voltage fluctuations and
flicker
EN 61000-3-3: 2013
Radio frequency interference
EN 55015: 2013
Immunity standard
EN 61547: 2009
Performance requirements
EN 62384: 2006+
A1:2009
Digital addressing lighting interface:
General requirements for DALI system
Requirements for DALI control gear
Requirements for control gear of LED
modules (DALI Device Type 6)
EN 62386-101 (DALI-2)
EN 62386-102 (DALI-2)
EN 62386-207 (DALI-2)
Recommended Practices for
Modulating Current in High-Brightness
LEDs for Mitigating Health Risks to
Viewers
IEEE 1789-2015
Compliant with relevant EU directives
RoHS / REACH compliant
ENEC and CE / UKCA marked
Label symbols
Safety isolating control gear with short circuit protection
(SELV control gear).
Double insulated control gear suitable for built-in use.
Thermally controlled control gear, incorporating means
of protection against overheating to prevent the case
temperature under any conditions of use from exceeding
110
°C.
DALI-2 certified control gear.
03.11.2021 5/5
Information and conformity
T22 199 1A