HELVAR ActiveHeat 5680 Installation And Operating Instructions Download Page 2

WARRANTY AND LIABILITY:

Seller warrants that this product is free from defects
in manufacturing, materials and workmanship for a

period of two years. The liability of seller is limited

to   deliver   a   new   thermostat   per   faulty   one

according to warranty statement above. Seller has
right to receive faulty units to be checked. Seller's

liability   explicitly   excludes   everything   exceeding

above condi ons.

For more informa on:

www.taelek.fi/docume

 

 n  ts

    

   

The Bluetooth®

 trademark and logos are property of

Bluetooth SIG, Inc., and their usage is licensend for
Taelek   Oy.   Other   brands   and   trade   names   are

property of the respec ve owners.

Apple

, the Apple logo, iPhone, iPad, and iPod touch

are trademarks of Apple Inc., registered in the U.S.
and other countries. App Store is a service mark of

Apple Inc. 

Google

 Play and the Google Play logo are trademarks

of Google Inc.

EN 

BLE Thermostat

Installa on and opera ng 
instruc ons

BLE THERMOSTAT – SETUP

TECHNICAL SPECIFICATIONS

Bluetooth:

 Version  4.2

Power supply:

 230V - 50Hz

Maximum load:

 16A (resis ve)

Temperature range:

 +5°C/+35°C

External Temperature setback:

 230V - 50Hz

IP class:

 IP21

Standard Color:

 White

Sensors:

 Built-in room sensor, external floor 

sensor NTC and possibility to add wireless BLE 

temperature sensor.

INSTALLATION

Installa on   must   be   done   by   a   qualified
electrician   in   accordance   with   wiring   and

building   regula ons.   Before   installa on,

disconnect   any   power   to   the   thermostat’s

mains. 

Installa on   loca on   must   be   within   the   BLE

range of the nearest Ac ve Ahead movement

sensor (appr. 10m).

In a factory new thermostat the front cover (A)

and frame (B) are loose and you can just pull

them out. If the visual parts are fixed then push
the rotary dial (C°) hard downwards and while

holding it down turn an -clockwise. The front

cover and the frame can now be pulled away

easily. 

Connect the wires to the thermostat’s terminal:

SETBACK:

 External Setback Wire (if applicable),

HEATING (N):

  Hea ng Cable N connec on,  

N:

Power   N   connec on,  

FLOOR   SENSOR:

  Floor

temp sensor NTC, 

HEATING (L):

 Hea ng Cable L

connec on,  

L:

 Power L connec on.

Next,  install the  thermostat   in  wall  moun ng
box  and fasten it using 2-4 screws. Assemble

the frame. Check that fixing nails are in 'LOCK'

posi on.   If   not   use   screwdriver   to   push   to

correct  posi on.  Push the front  cover un l it
snaps in place. The front cover should now be

firmly fixed on all sides. 

STARTUP

A er connec ng the power to the thermostat

for the first  me thermostat recognizes if floor
sensor   is   connected   or   not   and   makes

ini aliza on accordingly (selects between floor

mode and air mode). Thermostat also ini alizes

the  user program so that all hours are green
(eco hours) and  Bluetooth is ready to receive

commands   from   presense   sensor   (receive

wireless   eco   controls   is   ON).   The   other

parameters are ini alized to default values:

Mode :

 Floor / Air

Floor temperature min :

 5°C / NaN

Floor temperature max :

 27°C / NaN

Name of thermostat :

 RANDOM number

User program ac vated eco temp :

 19°C 

Externally ac vated eco temp :

 19°C

Floor temperature offset (calibra on) :

 -3°C

Air temperature offset (calibra on) :

 0°C

Air temperature min :

 5°C

Air temperature max :

 28°C

PWM min :

 0%

PWM max :

 100%

Valve protec on :

 OFF

Sensor type :

 10k ohm

Led intensity :

 70%

Weekly program

 : AUTO

Use ecoControl App to check and modify 

se ngs.

BLE THERMOSTAT – USER MANUAL

BASIC USE

The   thermostat   is  in   eco   mode   by   default.

Temperature set point is defined by the parameter

User program ac vated eco temp

. User can modify

different 24h/7d week schedule  as well. Ac veAhead

occupancy   message   will   automa cally   force   the

comfort mode  for the next 10 minutes.  In comfort

mode the temperature set point is   defined by the
rotary   dial   (C°).   The   snow   flake   and   maximum

symbols   equal   to   “

min   and   max   temperature”

specified in se ngs. 

Eco   mode   can  also  be   selected   with   an   external

setback switch (230VAC). Target temperature for this

eco   mode   is   defined   in   “

Externally   ac vated   eco

temp

” se ng and the default value is 19°C.

Power touch bu on

If red and green leds are both OFF the thermostat is

in     stand-by   mode.   In   stand-by   mode   hea ng   is

forced   OFF   despite   of   temperature.   Touch   the

ON/OFF bu on to turn the thermostat ON. 
- red led on → target temp selected by dial is reached

- red led fluctua ng → hea ng is on

- green led ON → eco temp se ng value reached

- green led fluctua ng → hea ng is on
Touching the ON/OFF bu on when either of the leds

is ON turns the device in stand-by mode.

ADVANCED USE

User may use a mobile device with ecoControl App

(Android / iOS) to read log temperatures,  to make

se ngs and define a weekly user program. App also
can   generate   email   reports.   Follow   the   guides   in