Placement of the HE-TPS01 is of utmost importance for proper operation and must be away from sunlight and sources of direct heat.
We recommend installing the HE-TPS01 approximately 1.5 meters above the floor.
Remove the touch panel unit and backplate of the HE-TPS01 from the packaging.
FIRST ENSURE THE POWER IS OFF at the main circuit breaker, and then test the wires with a probe or multimeter to verify. Insert the
wires to the correct HE-TPS01 terminals by inserting a small Phillips-head screwdriver into the slot beneath each terminal and unscrew
to open.
Follow connection diagrams on Figure 1 or 2 and the instructions below:
• Power wires:
For AC power (85-265VAC) connect Line & Neutral lead wires to L & N terminals labeled “POWER”. For DC power
(24-48VDC) connect “+” wire to terminal L and “–” wire to terminal N.
• Source wire:
Connect the required power source for relay to the terminal labeled “IN 1-3”.
• Load:
Connect the required load to the relay output terminal labeled “OUT-1”.
Note:
HELTUN recommends installing cord terminals (electric wire ferrules) on the ends of wires before connecting them to the
HE-TPS01 (various colors terminals are included).
Note:
Zero-Cross technology is unavailable if the device uses DC voltage (24-48VDC).
Tighten wires using Phillips screwdriver in slot beneath each wire.
Making sure the HE-TPS01 backplate is oriented on the wall with the word “TOP” pointed upwards, secure the backplate to the electrical
junction box using the four provided screws (do not overtighten).
Once the backplate is secured onto the wall, assemble the HE-TPS01 touch panel unit onto the backplate by first carefully aligning the
two top snap connectors, and then gently pushing the entire panel unit until it ‘snaps’ into position all the way around.
Next, switch On the main power at the circuit breaker. The HE-TPS01 will start up showing the original default factory settings.
Remove the clear protective film from the touch panel unit by pulling on the top right-hand tab.
1.
2.
3.
4.
5.
6.
INSTALLATION
The HELTUN HE-TPS01 Touch Panel Switch ‘Solo’ must be installed by a licensed electrician in a manner that conforms to local regulations
and building codes. Provide these instructions to the licensed electrician who is installing the HE-TPS01.
WARNING: Electrical power must be switched off during installation.