24
/
30
HTE029A1
15
HANDLING
,
SAFETY AND ENVIROMENTALREQUIREMENTS
WARNING
The display glass may break when it is dropped or bumped on a hard surface. Handle with care. Should the display
break, do not touch the electrophoretic material. In case of contact with electrophoretic material, wash with water and
soap.
CAUTION
The display module should not be exposed to harmful gases, such as acid and alkali gases, which corrode electronic
components.
Disassembling the display module can cause permanent damage and invalidate the warranty agreements.
IPA solvent can only be applied on active area and the back of a glass. For the rest part, it is not allowed.
Observe general precautions that are common to handling delicate electronic components. The glass can break and
front surfaces can easily be damaged . Moreover the display is sensitive to static electricity and
other rough environmental conditions.
Mounting Precautions
(1) It`s recommended that you consider the mounting structure so that uneven force (ex. Twisted stress) is not applied to
the module.
(2) It`s recommended that you attach a transparent protective plate to the surface in order to protect the EPD.
Transparent protective plate should have sufficient strength in order to resist external force.
(3) You should adopt radiation structure to satisfy the temperature specification.
(4) Acetic acid type and chlorine type materials for the cover case are not desirable because the former generates
corrosive gas of attacking the PS at high temperature and the latter causes circuit break by electro-chemical reaction.
(5) Do not touch, push or rub the exposed PS with glass, tweezers or anything harder than HB pencil lead. And please do
not rub with dust clothes with chemical treatment. Do not touch the surface of PS for bare hand or greasy cloth. (Some
cosmetics deteriorate the PS)
(6) When the surface becomes dusty, please wipe gently with absorbent cotton or other soft materials like chamois soaks
with petroleum benzene. Normal-hexane is recommended for cleaning the adhesives used to attach the PS. Do not use
acetone, toluene and alcohol because they cause chemical damage to the PS.
(7) Wipe off saliva or water drops as soon as possible. Their long time contact with PS causes deformations and color
fading.
Product specification
The data sheet contains final product specifications.