5. Cables and fuses for heaters 1105
– XX (SKLE / Laava)
Model
Power
kW
Sauna heaters con-
nection cable
H07RN-F /
60245 IEC 66
mm
2
400
– 415V 3N~
Fuse
A
Sauna heaters
connection cable
H07RN-F /
60245 IEC 66
mm
2
230V 3~
Fuse
A
1105 - 901
1105 -1051
1105 -1201
1105 -1501
9,0
10,5
12,0
15,0
5 x 2,5
5 x 2,5
5 x 6
5 x 6
3 x 16
3 x 16
3 x 25
3 x 25
4 x 6
---------
---------
---------
3 x 25
---------
---------
---------
Table 2 Kables and fuses for heater 1105
– XX (SKLE / Laava)
6. Safety clearances for sauna heaters 1106
– XX (SKLF / Octa)
Figure 3. Safety clearances to heater SKLF / Octa
Table 3 Safety clearances to heater 1106
– xx (SKLF / Octa)
Power
Sauna room
Safety clearances min
Adequate amount
of stones
kW
Volum
m
3
Min height
H
mm
On the sides
A
mm
In front
D
mm
To the ceiling
F
mm
Approx. kg
9,0
10,5
12,0
15,0
8-13
9-15
10-18
14-24
1900
1900
2100
2100
25
25
65
65
25
25
65
65
1150
1150
1350
1350
60
60
60
60
User and installation manual
WE 40
6
1. Contactor box WE 40
2. Sensor OLET 31
3. Temperature resistant cable for sensor
4. Feed cable to the sauna heater
5. Connection box
6. Connection cable to the sauna heater
7. Lower bench or railing
8. Upper bench or railing
9. Control centre Trend or Premium wifi
A min 560 D min
10 10
max
500
max
500
min
H
min
F
760
OLET 31
1
2
3
4
7
8
9
5
6
1106-
… Octa
NOTE: The OLET 31
sensor is installed
directly on the ceiling,
in line with the side of
the heater.
Sensor installation area
Heater