Sauna heater safety clearances
Figure. Heater installation to wall
Figure. Heater safety distances and sensor position to wall 40 mm from ceiling
Table. Safety clearances
Power
Saunaroom
Minimum distance to
Stone
kW
Volume
Height
Side
wall
A
mm
In front
of
D
mm
Ceiling
F
mm
Floor
K
mm
B
mm
J
mm
Min Max
Circa kg Circa kg
min.
m³
max.
m³
min. mm
4,5
3
6
1900
40
60
1200
110
105
390
12
20
6,0
5
9
1900
60
80
1200
110
125
390
12
20
8,0
8
12
1900
80
100
1200
110
145
390
20
20
Screw 6 x 40 mm (2 pcs)
Screw 6 x 16 mm (2 pcs)
Minimum distances for
the mounting (mm)
Drill. Ø3,5 mm
K
A 402 A
m
in
2
0
min 30
m
in
2
0
min 30
F
m
in
1
9
0
0
270 D
OLET 31
(mm)
OLET 31
Absolute measure of 40mm from ceiling
Absolute measure of
40mm from ceiling
Figure. Alternative installation location
for the sensor OLET 31 when using the
contactor casing WE 40 and the Pure or
Elite control panel.
OLET 31
K
m
in
2
0
min 30
F
m
in
1
9
0
0
270 D
(mm)
OLET 31