Remote controlling
The Heater can be remotely controlled by connecting a closed contactor,
which can be pulse triggered, to connectors 3 and 4 of a RJ10 circuit board.
The recommended cable size is AWG 24 or 26.
The maximum length of an AWG 24 cable is 200 m.
The maximum length of an AWG 26 cable is 130 m.
Principle coupling when Pure is used
as control panel
Table. Connection cable and fuses
Connection of the sauna heater to the mains
The sauna heater must be connected to the mains by a qualified electrician and in compliance with current regulations. The
sauna heater is connected with a semi-permanent connection. Use H07RN-F (60245 IEC 66) cables or a corresponding type.
Other output cables (signal lamp, electric heating toggle) must also adhere to these recommendations. Do not use PVC
insulated cable as a connection cable for the sauna heater.
Helo Water Tech (Helo-WT) in a Himalaya heater
Helo-WT uses the heater's thermal energy to heat water and raise the moisture level without a separate heat source.
Moisturised air improves the sauna climate, and various fragrances and salts can be evaporated to make the sauna experience
more enjoyable.
For additional information about Helo-WT :
Power
kW
Sauna heater’s
connection cable
H07RN
–F/ 60245
IEC 66
mm²
400V 3N~
Fuse
A
Sauna heater’s
connection cable
H07RN
–F/ 60245
IEC 66
mm²
230V 3~
Fuse
A
Sauna heater’s
connection cable
H07RN
–F/ 60245
IEC 66
mm²
230V 1 N~ / 2~
Fuse
A
6,8
5 x 1,5
3 x 10
4 x 4
3 x 20
3 x 6
1 x 35
10,5
5 x 2,5
3 x 16
4 x 6
3 x 35
----------
--------
Door switch
The door switch refers to the switch on the sauna door. This switch com-
plies with regulations. Public and private saunas must have a door switch,
i.e. saunas where the heater can be switched on from outside the sauna,
e.g. using an On/Off button or a similar method.
For additional information about door switch. www.tylohelo.com
Magnet on
the door
Max 18 mm
Door switch Min. 300 mm Junction box
Door switch
position when
installed on
lower part of the
door
4
3
2
1
Heater
Sensor cable
Terminal block
Limiter
1 = Blue
2 = White
3 = Red
4 = Yellow
Sensor OLET 31
OLEA 103
Heater
A1 Yellow
A2 Green
A3 Red
A4 Black
Apter circuit board
OLEA 103
Control panel
pure