Helo HELO CAVA DET Installation And User Manual Download Page 6

 

 

3.3. 

Various stages of the installation 

 

 

3.3.1. 

Mounting the sauna heater to the wall 

 
 
With the adjustment legs driven in, the mounting height of the sauna 
heater wall mount is 750mm from the floor. 
 
The adjustment legs can be adjusted 15mm in case the floor is inclined. 
After the mounting, check that both adjustment legs are evenly against 
the floor. 
 
 The distance between the holes for the mount in the wall is 240mm. 
 
 
Parts for wall mounting: 
 
   - sauna heater locking wedges (A) 

2 pcs 

   - wall fastening (B) 

 

1 pc 

   - sheet metal screw 4.2 x 13mm 

2 pcs 

   - build screw 6 x 40mm      

 

2 pcs 

 
 
Pass the locking wedges (A) through the holes in the heater 
so 
that the ingoing part is turned upwards. 
 
The wall mount (B) is attached to the wall so that the holes 
where the locking wedges are secured to are upwards.  
 
The mount may also be attached directly to the sauna heater. 
Mark the locations of the screws on the wall and, if 
necessary, drill small holes and mount the sauna  
heater then to the wall with the screws provided. 
 
The picture shows how the wall mount should be attached to 
the sauna heater. The locking wedges are attached to the 
wall mount with the sheet metal screws. 
 

 
              Image 1 

Mounting the sauna heater to the wall 

 

 

 

 

 

 

 

 

 

A

B

Installation and User Manual  HELO CAVA / HELO ROXX DET 

Drill diam. o 3,5 mm

M

in

 75

0 mm 

 M

ax 

765

 m

m

Min.
240 mm

240

240 mm

An additional foot stand (0043105) is available as an accessory. It will 
rise the heater 150 mm from the floor. 

The installation instructions are enclosed in the packaging. 

Summary of Contents for HELO CAVA DET

Page 1: ...0 040518 Helo Cava DET 1118 90 040518 Helo Cava DET 1118 600 040518 Helo Roxx DET 1118 900 040518 Helo Roxx DET CONTROL PANELS 1601 27 T 1 314 SKLT 53 3 A Installation and User Manual HELO CAVA HELO R...

Page 2: ...m ventilation 10 3 5 Connection of the sauna heater to the mains 10 3 6 Electric heating toggle 11 3 7 Sauna heater safety clearances 11 3 8 Locating the connecting box for the connection cable in the...

Page 3: ...while supervised or according to instructions given by the persons in charge of their safety Make sure that children aren t playing with the sauna heater 2 1 Sauna room The walls and ceiling of a saun...

Page 4: ...der to enhance ventilation between the stones Do not bend the heating elements together or against the frame Rearrange the stones regularly at least once a year and replace small and broken stones wit...

Page 5: ...supply cable mm for the sauna heater in question 5 Conform to the specified safe clearance around the sauna heater Please refer to table 1 on page 11 6 There should be enough room around the sauna hea...

Page 6: ...art is turned upwards The wall mount B is attached to the wall so that the holes where the locking wedges are secured to are upwards The mount may also be attached directly to the sauna heater Mark th...

Page 7: ...es 8 of the soapstones so that the projection will always stay on the stone i e there will always be an air gap between the stones The metal pieces are placed on each side between each stone except th...

Page 8: ...ertical limiters The soapstones also remain between the vertical limiters End limiter The illustration shows the installed supports The soapstones are installed as follows Install the upper stone firs...

Page 9: ...n shows both the vertical and horizontal limiters of the soapstones Install the middle stones The length of the middle stones is 405mm Push the stone first under the right edge and then along the supp...

Page 10: ...mains by a qualified electrician and in compliance with current regulations The sauna heater is connected with a semi permanent connection Use H07RN F 60245 IEC 66 cables or a corresponding type Other...

Page 11: ...rolling the electric heating toggle Connector 55 and the heating elements are simultaneously live 230V 3 7 Sauna heater safety clearances NOTE The thermostat is installed at a distance of 40mm from th...

Page 12: ...le in the sauna room Image 5 Location for the connection box A Specified minimum safety clearance 1 Recommended location for the connecting box 2 Silumin box recommended in this area 3 This area shoul...

Page 13: ...Limiter Connector strip Sensor cable Heater Control panel T1 Sensor OLET 28 Sauna heater Silicone 4 x 0 25 Control panel T1 LiYCY 10 x 0 25 Input 230 240V 1N 2 230V 3 400 415V 3N Heater Senosr OLET 28...

Page 14: ...omnetz Power input 2 S hk l mmityksen vuorottelu El f rregling av annan el f rbrukare Signal kontakt Signal contact 3 Saunavalo Bastu belysning Saunabeleuchtung Sauna light max 100W 4 Ohjauskeskus Sty...

Page 15: ...elief 1 1 4 7812550 Mains connector NLWD 1 1 1 1 5 6214036 Thermostat OLET 28 1 1 6 4316221 Heating element SEPC 64 3 6 5207518 Heating element SEPC 65B 3 7 5320517 Contactor OKTA 5 1 2 2 8 6119649 Ro...

Page 16: ...rotection This product must not be disposed with normal household waste at the end of its life cycle Instead it should be delivered to a collecting place for the recycling of electrical and electronic...

Reviews: