Effect
Heater connection
cable H07RN-F/
60245 IEC 66
mm
2
400-415V 3N~
Fuse
A
Heater connection
cable H07RN-F/
60245 IEC 66
mm
2
230V 3~
Fuse
A
Heater connection
cable H07RN-F/
60245 IEC 66
mm
2
230-240V 1N~ / 2~
Fuse
A
4,5
6,0
8,0
5 x 1,5
5 x 1,5
5 x 2,5
3 x 10
3 x 10
3 x 16
4 x 2,5
4 x 2,5
4 x 6
3 x 16
3 x 16
3 x 25
3 x 4,0
3 x 6,0
3 x 6,0
1 x 20
1 x 35
1 x 35
Table 2 Connection cable and fuse
3.4 Electric heating toggle
Electric heating toggle applies to homes with an electric heating system.
Sauna heater has connections (marked N - 55) for controlling the electric heating toggle. Connectors N - 55 and the heating
elements are simultaneously live (230V). The sauna heater thermostat also controls the heating toggle. In other words,
home heating turns on once the sauna thermostat cuts power off the sauna heater.
Image 3 Location for the connection box
3.5 Location the connection box for connection cable in the sauna room
A = Specified minimum safety clearance
1. Recommended location for the connection box
2. Silumin box recommended in this area.
3. This area should be avoided. Always use a silumin box.
In other areas, use a heat-
-
must be clear of obstacles. When installing the connection box to zones 2 or 3, refer to the instructions and reg-
ulations of the local energy supplier.
Product Manual
Ring Wall STJ
11
A
A
3.
2.
1.
A A